Evidence map›Paper›PMID 20376077›Full record

SynthesisJournal of human hypertension2010

Determining which automatic digital blood pressure device performs adequately: a systematic review.

Y Wan, C Heneghan, R Stevens, R J McManus, A Ward, R Perera, M Thompson, L Tarassenko, D Mant

Abstract readSystematic Review
In one paragraph

Synthesis in Journal of human hypertension, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Trial
  5. Trial
  6. Trial
  7. Observational
  8. Article
  9. Article
  10. Article
  11. Real-Time Blood Pressure Estimation From Force-Measured Ultrasound.IEEE transactions on bio-medical engineering · 2018
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Y WanDepartment of Health Statistics, Fourth Military Medical University, Xi'an, China.
C Heneghan
R Stevens
R J McManus
A Ward
R Perera
M Thompson
L Tarassenko
D Mant

Funding

Department of Health CDF/01/017Department of Health PB-PG-1207-15042
6 · The paper itself

Abstract

The aim of this study is to systematically examine the proportion of accurate readings attained by automatic digital blood pressure (BP) devices in published validation studies. We included studies of automatic digital BP devices using recognized protocols. We summarized the data as mean and s.d. of differences between measured and observed BP, and proportion of measurements within 5 mm Hg. We included 79 articles (10,783 participants) reporting 113 studies from 22 different countries. Overall, 25/31 (81%), 37/41 (90%) and 34/35 (97%) devices passed the relevant protocols [BHS, AAMI and ESH international protocol (ESH-IP), respectively]. For devices that passed the BHS protocol, the proportion of measured values within 5 mm Hg of the observed value ranged from 60 to 86% (AAMI protocol 47-94% and ESH-IP 54-89%). The results for the same device varied significantly when a different protocol was used (Omron HEM-907 80% of readings were within 5 mm Hg using the AAMI protocol compared with 62% with the ESH-IP). Even devices with a mean difference of zero show high variation: a device with 74% of BP measurements within 5 mm Hg would require six further BP measurements to reduce variation to 95% of readings within 5 mm Hg. Current protocols for validating BP monitors give no guarantee of accuracy in clinical practice. Devices may pass even the most rigorous protocol with as few as 60% of readings within 5 mm Hg of the observed value. Multiple readings are essential to provide clinicians and patients with accurate information on which to base diagnostic and treatment decisions.

Indexed as

Blood Pressure MonitorsHumansHypertensionReproducibility of ResultsValidation Studies as Topic

Identifiers

PMID20376077
PMCPMC2897978

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.