Evidence map›Paper›PMID 20361268›Full record

ArticleMedical & biological engineering & computing2010

Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement.

Seung Min Lee, Kyo Sik Sim, Ko Keun Kim, Yong Gyu Lim, Kwang Suk Park

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.8field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 56 citations in OpenAlex.

  1. Noise-Reducing Fabric Electrode for ECG Measurement.Sensors (Basel, Switzerland) · 2021
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Graphene-Enabled Electrodes for Electrocardiogram Monitoring.Nanomaterials (Basel, Switzerland) · 2016
    Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 3 countries.

Seung Min LeeGraduate Program in Bioengineering, Seoul National University, Seoul, Republic of Korea. smlee@bmsil.snu.ac.kr
Kyo Sik Sim
Ko Keun Kim
Yong Gyu Lim
Kwang Suk Park
Seoul National University · KRNew Generation University College · ETSangji University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Capacitive electrocardiogram (ECG) measurement over clothing requires large electrodes that can remain in contact with curved body surfaces to increase the signal-to-noise ratio (SNR). In this article, we propose a new, thin, and flexible active electrode for use as a capacitive ECG measurement electrode. This electrode contains a shielding plate over its surface and it is extremely thin and can bend freely to cover larger body surfaces of the curve-shaped human torso. We evaluated the characteristics of flexible active electrodes under conditions of varying cloth thickness, electrode size, and contacting pressure. Electrodes of two sizes (45 and 12 cm(2)) were attached to a chest belt to measure the ECG from the human torso, and the results obtained for both the sizes were compared. Cloth thickness and electrode size showed a dominant effect on the SNR, whereas contacting pressure had almost no effect. The flexible active electrodes attached to chest belts wrapped closely and uniformly over the curved surface of the torso and SNR was increased with an increase in electrode size. Although the ECG signal became more distorted as the cloth thickness increased, the larger-sized flexible active electrode (45 cm(2)) showed less distortion than the smaller-sized one (12 cm(2)).

Indexed as

ElectrodesClothingElectric CapacitanceElectrocardiographyElectronics, MedicalEquipment DesignHumans

Identifiers

PMID20361268
OpenAlexW2011649015

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.