ArticleAnalytical chemistry2010
Dual source ion mobility-mass spectrometer for direct comparison of electrospray ionization and MALDI collision cross section measurements.
Article in Analytical chemistry, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 28 citations in OpenAlex.
- Isomeric and Conformational Analysis of Small Drug and Drug-Like Molecules by Ion Mobility-Mass Spectrometry (IM-MS).Methods in molecular biology (Clifton, N.J.) · 2019Article
- Conformational Landscapes of Ubiquitin, Cytochrome c, and Myoglobin: Uniform Field Ion Mobility Measurements in Helium and Nitrogen Drift Gas.International journal of mass spectrometry · 2018Article
- Ion Mobility Collision Cross Section Compendium.Analytical chemistry · 2017Review
- Distance geometry protocol to generate conformations of natural products to structurally interpret ion mobility-mass spectrometry collision cross sections.The journal of physical chemistry. B · 2014Article
- Fluorometric beam profiling of UV MALDI lasers.Journal of the American Society for Mass Spectrometry · 2013Article
- Structural mass spectrometry: rapid methods for separation and analysis of peptide natural products.Journal of natural products · 2012Article
- Size, weight and position: ion mobility spectrometry and imaging MS combined.Analytical and bioanalytical chemistry · 2011Review
- Towards monitoring real-time cellular response using an integrated microfluidics-matrix assisted laser desorption ionisation/nanoelectrospray ionisation-ion mobility-mass spectrometry platform.IET systems biology · 2010Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
In this report, we describe a dual ionization source ion mobility-mass spectrometer (IM-MS) instrument platform for investigations that critically compare ion mobility collision cross section (CCS) measurements obtained from different ionization methods. The instrument incorporates both matrix-assisted laser desorption ionization (MALDI) and nanoelectrospray ionization (nESI) sources. The nESI source incorporates a keyhole geometry ion funnel design which facilitates axial ion focusing, accumulation, and generation of short duration (10-30 mus) ion pulses for use with the IM-MS. The IM-MS instrument operation is independent of which ionization source is used. This allows comparisons of collision cross section measurements to be made between both ion sources with minimal differences in the instrumental arrangement. The performance of the nESI ion source is evaluated by measuring the collision cross section values of the charge states of equine cytochrome c (z = 9-16), and values are in good agreement (<2% deviation) with those previously reported in the literature. Several charge states (z = 8-11) of cytochrome c exhibit multiple cross sectional features in the ion mobility analysis. An analysis of the tryptic peptides of cytochrome c formed by both ESI and MALDI demonstrate that, on average, +1 MALDI ions are similar in CCS to +1 ESI ions and are smaller than +2 ESI ions. The ion mobility resolving power with ESI (30-35) is comparable to that obtained using MALDI (35-40), which suggests that both sources produce sufficiently narrow ion pulses for the measurement to be predominately diffusion rather than gate pulse width limited.