ArticleSleep & breathing = Schlaf & Atmung2011
Perioperative practical experiences in using a level 2 portable polysomnography.
Article in Sleep & breathing = Schlaf & Atmung, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02796846 (The Association of CPAP Compliance and Nocturnal Hypoxemia in the Perioperative Period), which is not on this map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Association of CPAP Compliance and Nocturnal Hypoxemia in the Perioperative Period
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 42 citations in OpenAlex.
- Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: a systematic review and meta-analysis.CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne · 2014Pooled it
- The impact of semi-upright position on severity of sleep disordered breathing in patients with obstructive sleep apnea: a two-arm, prospective, randomized controlled trial.BMC anesthesiology · 2023Trial
- Level 2 Polysomnography for the Diagnosis of Sleep Disorders: A Health Technology Assessment.Ontario health technology assessment series · 2024Article
- STOP-Bang questionnaire screening for obstructive sleep apnea among Chinese patients with type 2 diabetes mellitus.Archives of medical science : AMS · 2018Article
- Identification of significant obstructive sleep apnoea in the obese patient: development of the novel DX-OSA score.Romanian journal of anaesthesia and intensive care · 2016Article
- Clinical Features of Obstructive Sleep Apnea That Determine Its High Prevalence in Resistant Hypertension.Yonsei medical journal · 2015Article
- Home-based diagnosis of obstructive sleep apnea by polysomnography type 2: accuracy, reliability, and feasibility.Sleep & breathing = Schlaf & Atmung · 2014Article
- Alternative scoring models of STOP-bang questionnaire improve specificity to detect undiagnosed obstructive sleep apnea.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2014Article
- Neck circumference and lowest oxygen saturation are independently associated with high coexistence of hypertension in obstructive sleep apnea.Yonsei medical journal · 2014Article
- Predictive performance of the STOP-Bang score for identifying obstructive sleep apnea in obese patients.Obesity surgery · 2013Article
- Assessment of a wireless headband for automatic sleep scoring.Sleep & breathing = Schlaf & Atmung · 2013Article
- High STOP-Bang score indicates a high probability of obstructive sleep apnoea.British journal of anaesthesia · 2012Article
- Obstructive sleep apnea devices for out-of-center (OOC) testing: technology evaluation.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2011Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe objective of the study is to test the hypothesis that a level 2 portable sleep device (Embletta X100) is a reliable alternative for standard PSG in surgical patients.
methodsAfter hospital ethics approvals, preoperative patients over 18 years old were recruited. The patients for validation underwent standard PSG and Embletta X100 simultaneously in a sleep laboratory before surgery. The other patients received sleep studies with Embletta X100 perioperatively. The correlation analysis and paired Student t test between variables from Embletta and from standard PSG were used to evaluate the accuracy of Embletta. The quality of PSG recordings with Embletta was summarized.
resultTwenty-one patients completed sleep study on both systems; ten females and ten males, age was 54 ± 11 and BMI was 36 ± 9. There was a significant correlation between the majority of parameters from standard PSG and Embeltta X100 with manual scoring. The inter-rater agreement was substantial to perfect at different AHI cutoffs with a Kappa coefficient of 0.69 to 1. A significant correlation between standard PSG and Embletta X100 with automatic scoring was found only in AHI and a few other parameters. In 385 patients, 1,002 perioperative PSG recordings were carried out with Embletta. Of them, 889(88.7%) were technically good and 90(9%) technically acceptable. Only 23 (2.3%) PSG recordings failed.
conclusionEmbletta X100, installed by a well-trained sleep technician, is a good alternative when standard PSG was not available or impractical. Manual scoring by a certified PSG technologist is the key for reliable results.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials