Evidence map›Paper›PMID 20212149›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2010

FRET measurements of kinesin neck orientation reveal a structural basis for processivity and asymmetry.

Douglas S Martin, Reza Fathi, Timothy J Mitchison, Jeff Gelles

Abstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Tunable dynamics of microtubule-based active isotropic gels.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2014
    Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Douglas S MartinDepartment of Biochemistry, MS009, Brandeis University, P.O. Box 549110, Waltham, MA 02454-9110, USA.
Reza Fathi
Timothy J Mitchison
Jeff Gelles

Funding

Single-molecule visualization of transcription regulation mechanismsR01GM081648 · NIGMS · BRANDEIS UNIVERSITY · PI JEFF GELLES · 2007 to 2026
$7.4M
MICROTUBULE DYNAMICS AND MITOTIC MECHANISMR01GM039565 · NIGMS · UNIVERSITY OF CALIFORNIA SAN FRANCISCO · PI MITCHISON, TIMOTHY J · 1988 to 2018
$6.2M
Functional Mechanisms of Processive Motor ATPasesR37GM043369 · NIGMS · BRANDEIS UNIVERSITY · PI GELLES, JEFF · 2002 to 2011
$5.0M
NIGMS NIH HHS R01 GM039565NIGMS NIH HHS R01 GM081648NIGMS NIH HHS R37 GM043369
6 · The paper itself

Abstract

As the smallest and simplest motor enzymes, kinesins have served as the prototype for understanding the relationship between protein structure and mechanochemical function of enzymes in this class. Conventional kinesin (kinesin-1) is a motor enzyme that transports cargo toward the plus end of microtubules by a processive, asymmetric hand-over-hand mechanism. The coiled-coil neck domain, which connects the two kinesin motor domains, contributes to kinesin processivity (the ability to take many steps in a row) and is proposed to be a key determinant of the asymmetry in the kinesin mechanism. While previous studies have defined the orientation and position of microtubule-bound kinesin motor domains, the disposition of the neck coiled-coil remains uncertain. We determined the neck coiled-coil orientation using a multidonor fluorescence resonance energy transfer (FRET) technique to measure distances between microtubules and bound kinesin molecules. Microtubules were labeled with a new fluorescent taxol donor, TAMRA-X-taxol, and kinesin derivatives with an acceptor fluorophore attached at positions on the motor and neck coiled-coil domains were used to reconstruct the positions and orientations of the domains. FRET measurements to positions on the motor domain were largely consistent with the domain orientation determined in previous studies, validating the technique. Measurements to positions on the neck coiled-coil were inconsistent with a radial orientation and instead demonstrated that the neck coiled-coil is parallel to the microtubule surface. The measured orientation provides a structural explanation for how neck surface residues enhance processivity and suggests a simple hypothesis for the origin of kinesin step asymmetry and "limping."

Indexed as

AnimalsBinding SitesBiophysical PhenomenaDrosophila ProteinsFluorescence Resonance Energy TransferFluorescent DyesKinesinsMicrotubulesModels, MolecularMolecular Motor ProteinsPaclitaxelProtein BindingProtein MultimerizationProtein Structure, QuaternaryRhodamines5-carboxytetramethylrhodamine succinimidyl esterDrosophila ProteinsFluorescent DyesKhc protein, DrosophilaKinesinsMolecular Motor ProteinsPaclitaxelRhodamines

Identifiers

PMID20212149
PMCPMC2851760

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.