Evidence map›Paper›PMID 20195762›Full record

ArticleAnnals of biomedical engineering2010

A stretching device for high-resolution live-cell imaging.

Lawrence Huang, Pattie S Mathieu, Brian P Helmke

Open access · greenAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
1.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 76 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Frontiers in bioengineering and biotechnology · 2019
    Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Lawrence HuangDepartment of Biomedical Engineering, University of Virginia, Charlottesville, VA 22908, USA.
Pattie S Mathieu
Brian P Helmke
University of Virginia · US

Funding

Engineering an Atherosclerosis-Resistant EndotheliumR01HL080956 · NHLBI · UNIVERSITY OF VIRGINIA · PI SCHWARTZ, MARTIN A · 2007 to 2011
$3.6M
Flow-Induced Cytoskeletal Mechanics in Endothelial CellsR01HL071958 · NHLBI · UNIVERSITY OF VIRGINIA CHARLOTTESVILLE · PI HELMKE, BRIAN P · 2004 to 2007
$1.0M
NHLBI NIH HHS HL-071958NHLBI NIH HHS HL-080956NHLBI NIH HHS R01 HL071958NHLBI NIH HHS R01 HL080956
6 · The paper itself

Abstract

Several custom-built and commercially available devices are available to investigate cellular responses to substrate strain. However, analysis of structural dynamics by microscopy in living cells during stretch is not readily feasible. We describe a novel stretch device optimized for high-resolution live-cell imaging. The unit assembles onto standard inverted microscopes and applies constant magnitude or cyclic stretch at physiological magnitudes to cultured cells on elastic membranes. Interchangeable modular indenters enable delivery of equibiaxial and uniaxial stretch profiles. Strain analysis performed by tracking fluorescent microspheres adhered onto the substrate demonstrated reproducible application of stretch profiles. In endothelial cells transiently expressing enhanced green fluorescent protein (EGFP)-vimentin and paxillin-DsRed2 and subjected to constant magnitude equibiaxial stretch, the two-dimensional strain tensor demonstrated efficient transmission through the extracellular matrix and focal adhesions. Decreased transmission to the intermediate filament network was measured, and a heterogeneous spatial distribution of maximum stretch magnitude revealed discrete sites of strain focusing. Spatial correlation of vimentin and paxillin displacement vectors provided an estimate of the extent of mechanical coupling between the structures. Interestingly, switching the spatial profile of substrate strain reveals that actin-mediated edge ruffling is not desensitized to repeated mechanostimulation. These initial observations show that the stretch device is compatible with live-cell microscopy and is a novel tool for measuring dynamic structural remodeling under mechanical strain.

Indexed as

Diagnostic ImagingActinsAnimalsCell Culture TechniquesCellsCells, CulturedCellular StructuresEndothelial CellsExtracellular MatrixFemaleFocal AdhesionsGreen Fluorescent ProteinsPaxillinRatsRats, Sprague-DawleyVimentinActinsenhanced green fluorescent proteinGreen Fluorescent ProteinsPaxillinVimentin

Identifiers

PMID20195762
PMCPMC3468334
OpenAlexW1969955215

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.