Evidence map›Paper›PMID 20184700›Full record

ArticleCases journal2009

Catheter related venous thrombosis with cooling and warming catheters: two case reports.

Bertrand Prunet, Guillaume Lacroix, Julien Bordes, Raphael Poyet, Erwan D'Aranda, Philippe Goutorbe

Abstract read
In one paragraph

Article in Cases journal, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Esophageal Temperature Management in Patients Suffering from Traumatic Brain Injury.Therapeutic hypothermia and temperature management · 2019
    Trial
  2. Trial
  3. Article
  4. Article
  5. A warning for warming catheters: interventional radiology's role.Diagnostic and interventional radiology (Ankara, Turkey) · 2020
    Article
  6. Article
  7. Article
  8. Article
  9. [Long-term use of an endovascular temperature catheter].Medizinische Klinik, Intensivmedizin und Notfallmedizin · 2014
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Bertrand PrunetIntensive Care Unit, Sainte Anne Hospital, Boulevard Sainte Anne, 83000 Toulon, France. bertrand.prunet@orange.fr
Guillaume Lacroix
Julien Bordes
Raphael Poyet
Erwan D'Aranda
Philippe Goutorbe

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIntravascular cooling and warming catheters are among a range of proliferating technologies used for temperature control. Complications related to the use of these devices are few, and no definitive evidence has been presented thus far to indicate any differences in complication rates between these balloon catheters and other central vein catheters. We report two cases of cooling and warming catheter-related venous thrombosis. They are the both first ones report of this kind in the literature. CASE PRESENTATION: The first case was a 17-year-old man admitted with severe head trauma. On day 6, he presented with severe intracranial hypertension, requiring increased medical treatment: mannitol osmotherapy, barbiturate-induced coma, and mild therapeutic hypothermia. A double-lumen Alsius CoolLine catheter was placed in the inferior veina cava via the left femoral vein and active cooling was begun. On day 10, physical examination of the left inguinal area and echo-doppler revealed catheter-related thrombophlebitis with left iliocaval vein occlusion. The second case was a 42-year-old man admitted with a severe burn. On day 2, the patient was taken to the operating room for the first staged excision of his burn wounds. A triple lumen Alsius Icy catheter was placed in the inferior vena cava via the right femoral vein and active core warming of the patient was begun. From day 2 to day 7, active core warming of the patient was maintained. On day 7, he presented with a septic thrombophlebitis. Echo-doppler revealed a 4-cm-long thrombus at the femoral catheter site with complete blood flow obstruction and blood cultures and catheter tip were positive for methicillin-resistant Staphylococcus aureus.

conclusionAlthough generally considered safe, cooling and warming catheters can be associated with mechanical complications such as catheter-related venous thrombosis. Intensivists who use these devices should be aware of this possible complication. Finally, as with any other invasive catheter, to reduce the risk of complications, the catheter should be removed promptly when no longer needed.

Identifiers

PMID20184700
PMCPMC2827041

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.