Evidence map›Paper›PMID 20181505›Full record

ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2010

Combining absorption and dispersion signals to improve signal-to-noise for rapid-scan EPR imaging.

Mark Tseitlin, Richard W Quine, George A Rinard, Sandra S Eaton, Gareth R Eaton

Abstract read
In one paragraph

Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Real-Time Monitoring of Photoinduced pH Jumps byThe journal of physical chemistry letters · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. EPR Everywhere.Applied magnetic resonance · 2021
    Review
  10. Rapid-Scan Electron Paramagnetic Resonance of Highly Resolved Hyperfine Lines in Organic Radicals.Chemphyschem : a European journal of chemical physics and physical chemistry · 2020
    Article
  11. Full cycle rapid scan EPR deconvolution algorithm.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017
    Article
  12. Rapid-scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017
    Review
  13. Review
  14. Article
  15. Article
  16. Digitally generated excitation and near-baseband quadrature detection of rapid scan EPR signals.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2014
    Article
  17. Rapid-scan EPR of immobilized nitroxides.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2014
    Article
  18. Article
  19. The world as viewed by and with unpaired electrons.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2012
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mark TseitlinDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80208, USA.
Richard W Quine
George A Rinard
Sandra S Eaton
Gareth R Eaton

Funding

Very Low Frequency EPR Imaging in Vivo Phisiology P41 EB02034P41EB002034 · NIBIB · UNIVERSITY OF CHICAGO · PI HALPERN, HOWARD J · 2003 to 2017
$16.1M
Rapid Scan Biomedical EPR Spectroscopy and ImagingR01EB000557 · NIBIB · UNIVERSITY OF DENVER (COLORADO SEMINARY) · PI EATON, GARETH R · 2002 to 2011
$4.0M
Rapid Scan Biomedical EPR Spectroscopy and ImagingR56EB000557 · NIBIB · UNIVERSITY OF DENVER (COLORADO SEMINARY) · PI EATON, GARETH R · 2007 to 2007
$494k
NIBIB NIH HHS EB000557NIBIB NIH HHS P41 EB002034NIBIB NIH HHS R01 EB000557NIBIB NIH HHS R56 EB000557
6 · The paper itself

Abstract

Direct detection of the rapid-scan EPR signal with quadrature detection and without automatic frequency control provides both the absorption and dispersion components of the signal. The use of a cross-loop resonator results in similar signal-to-noise in the two channels. The dispersion signal can be converted to an equivalent absorption signal by means of Kramers-Kronig relations. The converted signal is added to the directly measured absorption signal. Since the noise in the two channels is not correlated, this procedure increases the signal-to-noise ratio of the resultant absorption signal by up to a factor of square root 2. The utility of this method was demonstrated for 2D spectral-spatial imaging of a phantom containing three tubes of LiPc with different oxygen concentrations and therefore different linewidths.

Indexed as

AlgorithmsSignal Processing, Computer-AssistedElectron Spin Resonance SpectroscopyReproducibility of ResultsSensitivity and Specificity

Identifiers

PMID20181505
PMCPMC2856439

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.