ArticleSurgical endoscopy2010
Sentinel node procedure of the sigmoid using indocyanine green: feasibility study in a goat model.
Article in Surgical endoscopy, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 2 syntheses or guidelines pooled it, 26 citations in OpenAlex.
- Near-infrared fluorescence imaging for sentinel lymph node identification in colon cancer: a prospective single-center study and systematic review with meta-analysis.Techniques in coloproctology · 2019Pooled it
- Near-infrared fluorescence imaging for real-time intraoperative anatomical guidance in minimally invasive surgery: a systematic review of the literature.World journal of surgery · 2015Pooled it
- Exploring the Applications of Indocyanine Green in Robot-Assisted Urological Surgery: A Comprehensive Review of Fluorescence-Guided Techniques.Sensors (Basel, Switzerland) · 2023Review
- Optimization and use of near infrared imaging to guide lymph node collection in rhesus macaques (Macaca mulatta).Journal of medical primatology · 2022Article
- [Fluorescence-guided detection of lymph node metastases of gastrointestinal tumors].Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen · 2019Review
- Green indocyanine fluorescence in robotic abdominal surgery.Updates in surgery · 2018Review
- Fluorescent Imaging With Indocyanine Green During Laparoscopic Cholecystectomy in Patients at Increased Risk of Bile Duct Injury.Surgical innovation · 2017Article
- Advanced intraoperative imaging methods for laparoscopic anatomy navigation: an overview.Surgical endoscopy · 2013Review
- Near-infrared fluorescence imaging of liver metastases in rats using indocyanine green.The Journal of surgical research · 2012Article
- Near-infrared (NIR) laparoscopy for intraoperative lymphatic road-mapping and sentinel node identification during definitive surgical resection of early-stage colorectal neoplasia.Surgical endoscopy · 2012Article
- Inert coupling of IRDye800CW to monoclonal antibodies for clinical optical imaging of tumor targets.EJNMMI research · 2011Article
- The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery.Journal of surgical oncology · 2011Review
- Firefly® System and Organ Transillumination in Robotic Gynecologic Surgery.JSLS : Journal of the Society of Laparoendoscopic SurgeonsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe sentinel lymph node (SLN) procedure alter the strategy for the treatment of patients with colon cancer. New techniques emerge that may provide the surgeon with a tool for accurate intraoperative detection of the SLNs.
methodsAn SLN procedure of the sigmoid was used in six goats. During laparoscopy, the near-infrared dye indocyanine green (ICG) was injected into the subserosa of the sigmoid via a percutaneously inserted needle during four experiments and in the submucosa during colonoscopy in two experiments. After injection, the near-infrared features of a newly developed laparoscope were used to detect the lymph vessels and SLNs. At the end of the procedure, 2 h after injection, all the goats were killed, and autopsy was performed. During postmortem laparotomy, the sigmoid was removed and used for confirmation of ICG node uptake.
resultsIn all the procedures, the lymph vessels were easily detected by their bright fluorescent emission. In the first two experiments, no lymph nodes were detected. In the subsequent four experiments, human serum albumin was added to the ICG solution before injection to enable better lymph node entrapment. In all four experiments, at least one bright fluorescent lymph node was found after the lymph vessels had been tracked by their fluorescent guidance. The mean time between injection and SLN identification was 10 min. In two cases, the SLNs were located up to 5 mm into the fat tissue of the mesentery and were not seen by regular vision of the laparoscope. By switching on the near-infrared features of the scope, a clear bright dot became visible, which increased in intensity after opening of the mesentery.
conclusionThe SLN procedure for the sigmoid using near-infrared laparoscopy in the goat is a very promising technique. Achievements described in this report justify a clinical trial on the feasibility of ICG-guided SLN detection in humans.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.