Evidence map›Paper›PMID 20167684›Full record

Trial reportClinical journal of the American Society of Nephrology : CJASN2010

Median intradialytic blood pressure can track changes evoked by probing dry-weight.

Rajiv Agarwal, Robert P Light

Open access · greenAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Clinical journal of the American Society of Nephrology : CJASN, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.1field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 19 citations in OpenAlex.

  1. Shorter delivered dialysis times associate with a higher and more difficult to treat blood pressure.Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2013
    Trial
  2. Article
  3. Review
  4. Blood pressure in hemodialysis: targets?Current opinion in nephrology and hypertension · 2017
    Review
  5. Computer Aided Detection System for Prediction of the Malaise during Hemodialysis.Computational and mathematical methods in medicine · 2016
    Article
  6. Review
  7. Interdialytic hypertension-an update.Advances in chronic kidney disease · 2011
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Rajiv AgarwalDivision of Nephrology, Department of Medicine, Indiana University School of Medicine, and Richard L. Roudebush Veterans' Affairs Medical Center, Indianapolis, Indiana 46202, USA. ragarwal@iupui.edu
Robert P Light
Indiana University · USIndiana University School of Medicine

Funding

Hypertension in Hemodialysis PatientsR01DK062030 · NIDDK · INDIANA UNIV-PURDUE UNIV AT INDIANAPOLIS · PI AGARWAL, RAJIV · 2003 to 2013
$3.8M
NIDDK NIH HHS 2R01-DK062030-06NIDDK NIH HHS R01 DK062030
6 · The paper itself

Abstract

backgroundMedian BP obtained over a single dialysis treatment can diagnose hypertension among hemodialysis patients. Whether median BP is as useful to track change in BP is unknown. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Among patients participating in the dry-weight reduction in hypertensive hemodialysis patients (DRIP) trial, interdialytic ambulatory BP was recorded at baseline, 4 weeks, and 8 weeks. The mean interdialytic ambulatory BP was compared to the following recordings: predialysis on one dialysis treatment (Pre1), predialysis averaged over 2 weeks of dialysis treatment (Pre6), postdialysis on one dialysis treatment (Post1), postdialysis averaged over 2 weeks of dialysis treatment (Post6), and median intradialytic BP over one treatment.

resultsPre1 was unable to detect change in ambulatory BP. Although Pre6 was able to detect change, it overestimated the ambulatory BP. On average, the magnitude of reduction in Post1 in response to probing dry-weight was nearly twice that obtained by ambulatory BP monitoring. Even Post6 overestimated the magnitude of reduction in BP at 8 weeks. Median systolic BP was responsive to probing dry-weight and neither overestimated nor underestimated the interdialytic ambulatory systolic BP at baseline or over time. However, the SD of the differences between median systolic BP and interdialytic ambulatory systolic BP varied from 16 to 20 mmHg.

conclusionsMedian intradialytic BP recordings can detect change in ambulatory BP evoked by reduction in dry-weight at the population level. Because of wide agreement limits between intradialytic and interdialytic BP, the individual prediction of ambulatory BP from median intradialytic BP can be misleading.

Indexed as

Blood PressureBlood Pressure Monitoring, AmbulatoryRenal DialysisFemaleHumansHypertensionKidney DiseasesMaleMiddle AgedPredictive Value of TestsProspective StudiesReproducibility of ResultsTime Factors

Identifiers

PMID20167684
PMCPMC2863982
OpenAlexW1998206532

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.