Evidence map›Paper›PMID 20167182›Full record

ArticleJournal of diabetes science and technology2010

Aluminum gallium nitride (GaN)/GaN high electron mobility transistor-based sensors for glucose detection in exhaled breath condensate.

Byung Hwan Chu, Byoung Sam Kang, Sheng Chun Hung, Ke Hung Chen, Fan Ren, Andrew Sciullo, Brent P Gila, Stephen J Pearton

Abstract readEvaluation Study
In one paragraph

Article in Journal of diabetes science and technology, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Review
  3. Low-Power pH Sensor Based on Narrow Channel Open-Gated AlMaterials (Basel, Switzerland) · 2020
    Article
  4. Article
  5. Noninvasive glucose detection in exhaled breath condensate.Translational research : the journal of laboratory and clinical medicine · 2019
    Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Byung Hwan ChuDepartment of Chemical Engineering, University of Florida, Gainesville, Florida, USA.
Byoung Sam Kang
Sheng Chun Hung
Ke Hung Chen
Fan Ren
Andrew Sciullo
Brent P Gila
Stephen J Pearton

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImmobilized aluminum gallium nitride (AlGaN)/GaN high electron mobility transistors (HEMTs) have shown great potential in the areas of pH, chloride ion, and glucose detection in exhaled breath condensate (EBC). HEMT sensors can be integrated into a wireless data transmission system that allows for remote monitoring. This technology offers the possibility of using AlGaN/GaN HEMTs for extended investigations of airway pathology of detecting glucose in EBC without the need for clinical visits.

methodsHEMT structures, consisting of a 3-microm-thick undoped GaN buffer, 30-A-thick Al(0.3)Ga(0.7)N spacer, and 220-A-thick silicon-doped Al(0.3)Ga(0.7)N cap layer, were used for fabricating the HEMT sensors. The gate area of the pH, chloride ion, and glucose detection was immobilized with scandium oxide (Sc(2)O(3)), silver chloride (AgCl) thin film, and zinc oxide (ZnO) nanorods, respectively.

resultsThe Sc(2)O(3)-gated sensor could detect the pH of solutions ranging from 3 to 10 with a resolution of approximately 0.1 pH. A chloride ion detection limit of 10(-8) M was achieved with a HEMT sensor immobilized with the AgCl thin film. The drain-source current of the ZnO nanorod-gated AlGaN/GaN HEMT sensor immobilized with glucose oxidase showed a rapid response of less than 5 seconds when the sensor was exposed to the target glucose in a buffer with a pH value of 7.4. The sensor could detect a wide range of concentrations from 0.5 nM to 125 microM.

conclusionThere is great promise for using HEMT-based sensors to enhance the detection sensitivity for glucose detection in EBC. Depending on the immobilized material, HEMT-based sensors can be used for sensing different materials. These electronic detection approaches with rapid response and good repeatability show potential for the investigation of airway pathology. The devices can also be integrated into a wireless data transmission system for remote monitoring applications. This sensor technology could use the exhaled breath condensate to measure the glucose concentration for diabetic applications.

Indexed as

ExhalationTransistors, ElectronicAluminum CompoundsBiosensing TechniquesBreath TestsComputer SystemsElectrochemistryElectronsExudates and TransudatesGalliumGlucoseHumansModels, BiologicalMonitoring, AmbulatoryNanotechnologyNanotubesAluminum Compoundsaluminum gallium nitrideGalliumgallium nitrideGlucose

Identifiers

PMID20167182
PMCPMC2825639

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.