A review of standards and statistics used to describe blood glucose monitor performance.

Jan S Krouwer, George S Cembrowski

Open access · bronzeAbstract readEvaluation StudyReview
In one paragraph

Review in Journal of diabetes science and technology, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 48 papers.

0numbers the graph read from it
0cells of the map it votes in
48citing papers in PubMed
7.0field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

48 citing papers in PubMed, 96 citations in OpenAlex.

  1. Trial
  2. Performance of the CONTOUR® TS Blood Glucose Monitoring System.Journal of diabetes science and technology · 2011
    Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Utility of point-of-care vs reference laboratory testing for the evaluation of glucose levels.Diabetic medicine : a journal of the British Diabetic Association · 2019
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Why the New FDA Glucose Meter POCT Guidance Is Disappointing.Journal of diabetes science and technology · 2017
    Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Jan S KrouwerKrouwer Consulting, Sherborn, Massachusetts 01770, USA. jan.krouwer@comcast.net
George S Cembrowski
Alberta Health Services · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Glucose performance is reviewed in the context of total error, which includes error from all sources, not just analytical. Many standards require less than 100% of results to be within specific tolerance limits. Analytical error represents the difference between tested glucose and reference method glucose. Medical errors include analytical errors whose magnitude is great enough to likely result in patient harm. The 95% requirements of International Organization for Standardization 15197 and others make little sense, as up to 5% of results can be medically unacceptable. The current American Diabetes Association standard lacks a specification for user error. Error grids can meaningfully specify allowable glucose error. Infrequently, glucose meters do not provide a glucose result; such an occurrence can be devastating when associated with a life-threatening event. Nonreporting failures are ignored by standards. Estimates of analytical error can be classified into the four following categories: imprecision, random patient interferences, protocol-independent bias, and protocol-dependent bias. Methods to estimate total error are parametric, nonparametric, modeling, or direct. The Westgard method underestimates total error by failing to account for random patient interferences. Lawton's method is a more complete model. Bland-Altman, mountain plots, and error grids are direct methods and are easier to use as they do not require modeling. Three types of protocols can be used to estimate glucose errors: method comparison, special studies and risk management, and monitoring performance of meters in the field. Current standards for glucose meter performance are inadequate. The level of performance required in regulatory standards should be based on clinical needs but can only deal with currently achievable performance. Clinical standards state what is needed, whether it can be achieved or not. Rational regulatory decisions about glucose monitors should be based on robust statistical analyses of performance.

Indexed as

Blood GlucoseBlood Glucose Self-MonitoringData Interpretation, StatisticalDiagnostic EquipmentDiagnostic ErrorsEfficiencyHumansHypoglycemiaMonitoring, AmbulatoryResearch DesignSensitivity and SpecificityBlood Glucose

Identifiers

PMID20167170
PMCPMC2825627
OpenAlexW2136364585

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.