ArticleSensors and actuators. B, Chemical2010
Osmotic Swelling Pressure Response of Smart Hydrogels Suitable for Chronically-Implantable Glucose Sensors.
Article in Sensors and actuators. B, Chemical, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 90 citations in OpenAlex.
- Optical imaging of microfluidic integrated smart hydrogels for research and sensing applications.Sensors and actuators. B, Chemical · 2025Article
- Anti-Obesity Drug Delivery Systems: Recent Progress and Challenges.Pharmaceutics · 2023Review
- Real-time and label-free biosensing using moiré pattern generated by bioresponsive hydrogel.Bioactive materials · 2023Article
- Thioflavin-modified molecularly imprinted hydrogel for fluorescent-based non-enzymatic glucose detection in wound exudate.Materials today. Bio · 2022Article
- Smart/stimuli-responsive hydrogels: Cutting-edge platforms for tissue engineering and other biomedical applications.Materials today. Bio · 2022Review
- Nanocellulose coated paper diagnostic to measure glucose concentration in human blood.Frontiers in bioengineering and biotechnology · 2022Article
- Catheter-mounted smart hydrogel ultrasound resonators for intravenous analyte monitoring.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2021Article
- Albumin Microspheres as "Trans-Ferry-Beads" for Easy Cell Passaging in Cell Culture Technology.Gels (Basel, Switzerland) · 2021Article
- Convection-driven microfabricated hydrogels for rapid biosensing.The Analyst · 2020Article
- Passive and wireless, implantable glucose sensing with phenylboronic acid hydrogel-interlayer RF resonators.Biosensors & bioelectronics · 2020Article
- Hydrogels Based Drug Delivery Synthesis, Characterization and Administration.Pharmaceutics · 2019Review
- Low-Cost Microfluidic Sensors with Smart Hydrogel Patterned Arrays Using Electronic Resistive Channel Sensing for Readout.Gels (Basel, Switzerland) · 2018Article
- Remote Microwave and Field-Effect Sensing Techniques for Monitoring Hydrogel Sensor Response.Micromachines · 2018Article
- Swelling, Mechanics, and Thermal/Chemical Stability of Hydrogels Containing Phenylboronic Acid Side Chains.Gels (Basel, Switzerland) · 2017Article
- Stimuli sensitive polymers and self regulated drug delivery systems: a very partial review.Journal of controlled release : official journal of the Controlled Release Society · 2014Review
- Thermodynamic Analysis of the Selectivity Enhancement Obtained by Using Smart Hydrogels That Are Zwitterionic When Detecting Glucose With Boronic Acid Moieties.Sensors and actuators. B, Chemical · 2011Article
- Low power, biologically benign NIR light triggers polymer disassembly.Macromolecules · 2011Article
- Responsive hydrogels for label-free signal transduction within biosensors.Sensors (Basel, Switzerland) · 2010Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 2 countries.
Funding
Abstract
In the last few years, a new type of glucose-sensitive hydrogel (GSH) has been developed that shrinks with increasing glucose concentration due to the formation of reversible crosslinks The first osmotic swelling pressure results measured for any member of this new class of GSH are reported, so that their suitability for use in sensors combining pressure transducers and smart gels can be evaluated. Comparison is also made with results obtained for an older type of GSH that expands with increasing glucose concentration due to an increase in the concentration of counterions within the gel. The newer type of GSH exhibits both faster kinetics and weaker fructose interference, and therefore is more suitable for in vivo glucose sensing.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.