Evidence map›Paper›PMID 20144290›Full record

ArticleJournal of diabetes science and technology2009

Noninvasive ultrasonic glucose sensing with large pigs (approximately 200 pounds) using a lightweight cymbal transducer array and biosensors.

Eun-Joo Park, Jacob Werner, Joshua Beebe, Samantha Chan, Nadine Barrie Smith

Open access · bronzeAbstract read
In one paragraph

Article in Journal of diabetes science and technology, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.1field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Defining optimal permeant characteristics for ultrasound-mediated gastrointestinal delivery.Journal of controlled release : official journal of the Controlled Release Society · 2017
    Article
  4. Applicability and safety of dual-frequency ultrasonic treatment for the transdermal delivery of drugs.Journal of controlled release : official journal of the Controlled Release Society · 2015
    Article
  5. Review
  6. Review
  7. Ultrasound-mediated transdermal drug delivery: mechanisms, scope, and emerging trends.Journal of controlled release : official journal of the Controlled Release Society · 2011
    Review
  8. Review
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Eun-Joo ParkDepartment of Bioengineering, The Pennsylvania State University, University Park, PA 16802, USA. eup114@psu.edu
Jacob Werner
Joshua Beebe
Samantha Chan
Nadine Barrie Smith
Pennsylvania State University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo prevent complications in diabetes, the proper management of blood glucose levels is essential. Since conventional glucose meters require pricking fingers or other areas of the skin, a noninvasive method for monitoring blood glucose levels is desired. Using a lightweight cymbal transducer array, this study was conducted to noninvasively determine the glucose levels of pigs having a similar size to humans.

methodIn vivo experiments using eight pigs (approximately 200 pounds) were performed in five groups. A cymbal array with four biosensors was attached to the axillary area of the pig. The array was operated at 20 kHz at special peak-temporal peak intensity (I(sptp)) equal to 50 or 100 mW/cm(2) for 5, 10, or 20 minutes. After the ultrasound exposure, glucose concentrations of the interstitial fluid were determined using biosensors. For comparison, glucose levels of blood samples collected from the ear vein were measured by a commercial glucose meter.

resultIn comparison, glucose levels determined by a cymbal array and biosensor system were close to those measured by a glucose meter. After a 20-minute ultrasound exposure at I(sptp) = 100 mW/cm(2), the average glucose level determined by the ultrasound system was 175 +/- 7 mg/dl, which is close to 166 +/- 5 mg/dl measured by the glucose meter.

conclusionResults indicate the feasibility of using a cymbal array for noninvasive glucose sensing on pigs having a similar size to humans. Further studies on the ultrasound conditions, such as frequency, intensity, and exposure time, will be continued for effective glucose sensing.

Indexed as

Biosensing TechniquesTransducersUltrasonicsAcoustic StimulationAnimalsBlood GlucoseExtracellular FluidFeasibility StudiesGlucoseModels, AnimalSwineBlood GlucoseGlucose

Identifiers

PMID20144290
PMCPMC2769881
OpenAlexW2110703226

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.