Chemical effects in the separation process of a differential mobility/mass spectrometer system.

Bradley B Schneider, Thomas R Covey, Stephen L Coy, Evgeny V Krylov, Erkinjon G Nazarov

Abstract read
In one paragraph

Article in Analytical chemistry, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 46 papers.

0numbers the graph read from it
0cells of the map it votes in
46citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

46 citing papers in PubMed.

  1. Article
  2. Article
  3. A First Principle Model of Differential Ion Mobility: the Effect of Ion-Solvent Clustering.Journal of the American Society for Mass Spectrometry · 2019
    Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Separation and simultaneous quantitation of PGF2Acta pharmaceutica Sinica. B · 2018
    Article
  13. Article
  14. Maximizing Ion Transmission in Differential Mobility Spectrometry.Journal of the American Society for Mass Spectrometry · 2017
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Optimization of a New Aerodynamic Cylindrical FAIMS Device for Small Molecule Analysis.Journal of the American Society for Mass Spectrometry · 2017
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Bradley B SchneiderMDS Analytical Technologies, 71 Four Valley Drive, Concord, Ontario, Canada L4K 4V8. bradley.schneider@sciex.com
Thomas R Covey
Stephen L Coy
Evgeny V Krylov
Erkinjon G Nazarov

Funding

Sample Engineering CoreU19AI067773 · NIAID · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI FORNACE, ALBERT J · 2005 to 2024
$105.4M
NIAID NIH HHS U19 AI067773
6 · The paper itself

Abstract

In differential mobility spectrometry (also referred to as high-field asymmetric waveform ion mobility spectrometry), ions are separated on the basis of the difference in their mobility under high and low electric fields. The addition of polar modifiers to the gas transporting the ions through a differential mobility spectrometer enhances the formation of clusters in a field-dependent way and thus amplifies the high- and low-field mobility difference, resulting in increased peak capacity and separation power. Observations of the increase in mobility field dependence are consistent with a cluster formation model, also referred to as the dynamic cluster-decluster model. The uniqueness of chemical interactions that occur between an ion and cluster-forming neutrals increases the selectivity of the separation, and the depression of low-field mobility relative to high-field mobility increases the compensation voltage and peak capacity. The effect of a polar modifier on the peak capacity across a broad range of chemicals has been investigated. We discuss the theoretical underpinnings which explain the observed effects. In contrast to the result with a polar modifier, we find that using mixtures of inert gases as the transport gas improves the resolution by reducing the peak width but has very little effect on the peak capacity or selectivity. The inert gas helium does not cluster and thus does not reduce low-field mobility relative to high-field mobility. The observed changes in the differential mobility alpha parameter exhibited by different classes of compounds when the transport gas contains a polar modifier or has a significant fraction of inert gas can be explained on the basis of the physical mechanisms involved in the separation processes.