Evidence map›Paper›PMID 20107792›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2010

High throughput static and dynamic small animal imaging using clinical PET/CT: potential preclinical applications.

Nicolas Aide, Cédric Desmonts, Jean-Mathieu Beauregard, Thomas Beyer, Kathryn Kinross, Peter Roselt, Oliver Neels, Denis Agostini, Stéphane Bardet, Gérard Bouvard and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Review
  6. High-Throughput PET/CT Imaging Using a Multiple-Mouse Imaging System.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2020
    Article
  7. Assessment of alteration in liverEuropean journal of nuclear medicine and molecular imaging · 2018
    Observational
  8. Review
  9. Article
  10. European journal of nuclear medicine and molecular imaging · 2016
    Article
  11. Article
  12. Review
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Nicolas AideBioticla Team, EA1792, IFR 146 ICORE, GRECAN, François Baclesse Cancer Centre and Caen University, Caen, France. n.aide@baclesse.fr
Cédric Desmonts
Jean-Mathieu Beauregard
Thomas Beyer
Kathryn Kinross
Peter Roselt
Oliver Neels
Denis Agostini
Stéphane Bardet
Gérard Bouvard
Rodney J Hicks

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe objective of the study was to evaluate state-of-the-art clinical PET/CT technology in performing static and dynamic imaging of several mice simultaneously.

methodsA mouse-sized phantom was imaged mimicking simultaneous imaging of three mice with computation of recovery coefficients (RCs) and spillover ratios (SORs). Fifteen mice harbouring abdominal or subcutaneous tumours were imaged on clinical PET/CT with point spread function (PSF) reconstruction after injection of [18F]fluorodeoxyglucose or [18F]fluorothymidine. Three of these mice were imaged alone and simultaneously at radial positions -5, 0 and 5 cm. The remaining 12 tumour-bearing mice were imaged in groups of 3 to establish the quantitative accuracy of PET data using ex vivo gamma counting as the reference. Finally, a dynamic scan was performed in three mice simultaneously after the injection of (68)Ga-ethylenediaminetetraacetic acid (EDTA).

resultsFor typical lesion sizes of 7-8 mm phantom experiments indicated RCs of 0.42 and 0.76 for ordered subsets expectation maximization (OSEM) and PSF reconstruction, respectively. For PSF reconstruction, SOR(air) and SOR(water) were 5.3 and 7.5%, respectively. A strong correlation (r (2) = 0.97, p < 0.0001) between quantitative data obtained in mice imaged alone and simultaneously in a group of three was found following PSF reconstruction. The correlation between ex vivo counting and PET/CT data was better with PSF reconstruction (r (2) = 0.98; slope = 0.89, p < 0.0001) than without (r (2) = 0.96; slope = 0.62, p < 0.001). Valid time-activity curves of the blood pool, kidneys and bladder could be derived from (68)Ga-EDTA dynamic acquisition.

conclusionNew generation clinical PET/CT can be used for simultaneous imaging of multiple small animals in experiments requiring high throughput and where a dedicated small animal PET system is not available.

Indexed as

AnimalsEdetic AcidMicePhantoms, ImagingPositron-Emission TomographyTime FactorsTomography, X-Ray ComputedEdetic Acid

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.