Evidence map›Paper›PMID 20087776›Full record

ArticleAnnals of biomedical engineering2010

The effects of concentric ring electrode electrical stimulation on rat skin.

W Besio, V Sharma, J Spaulding

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. [Finite-element simulation and experimental investigation of nanosecond transcranial pulsed electric field propagation and distribution in a three-dimensional brain model].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026
    Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Noninvasive pacing during transfemoral implantation of the Edwards SAPIEN valve for tricuspid valve bioprosthesis stenosis.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2016
    Article
  9. Article
  10. Noninvasive transcranial focal stimulation via tripolar concentric ring electrodes lessens behavioral seizure activity of recurrent pentylenetetrazole administrations in rats.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2013
    Article
  11. Article
  12. Toward a noninvasive automatic seizure control system in rats with transcranial focal stimulations via tripolar concentric ring electrodes.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2012
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

W BesioElectrical, Computer, and Biomedical Engineering Department, University of Rhode Island, 4 East Alumni Avenue, Kingston, RI 02881, USA. besio@ele.uri.edu
V Sharma
J Spaulding

Funding

Anticonvulsant effects of novel concentric ring electrode electrical stimulationR21NS061335 · NINDS · UNIVERSITY OF RHODE ISLAND · PI BESIO, WALTER GRANT · 2009 to 2010
$397k
NINDS NIH HHS R21 NS061335
6 · The paper itself

Abstract

Surface electrodes are commonly used electrodes clinically, in applications such as functional electrical stimulation for the restoration of motor functions, pain relief, transcutaneous electrical nerve stimulation, electrocardiographic monitoring, defibrillation, surface cardiac pacing, and advanced drug delivery systems. Common to these applications are occasional reports of pain, tissue damage, rash, or burns on the skin at the point where electrodes are placed. In this study, we quantitatively analyzed the effects of acute noninvasive electrical stimulation from concentric ring electrodes (CRE) to determine the maximum safe current limit. We developed a three-dimensional multi-layer model and calculated the temperature profile under the CRE and the corresponding energy density with electrical-thermal coupled field analysis. Infrared thermography was used to measure skin temperature during electrical stimulation to verify the computer simulations. We also performed histological analysis to study cell morphology and characterize any resulting tissue damage. The simulation results are accurate for low energy density distributions. It can also be concluded that as long as the specified energy density applied is kept below 0.92 (A2/cm4.s(-1)), the maximum temperature will remain within the safe limits. Future work should focus on the effects of the electrode paste.

Indexed as

ElectrodesModels, BiologicalAnimalsComputer SimulationElectric StimulationEquipment DesignEquipment Failure AnalysisRatsReproducibility of ResultsSensitivity and SpecificitySkin Temperature

Identifiers

PMID20087776
PMCPMC2905673

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.