ReviewEuropean journal of nuclear medicine and molecular imaging2010
Small-animal SPECT and SPECT/CT: application in cardiovascular research.
Review in European journal of nuclear medicine and molecular imaging, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 52 citations in OpenAlex.
- Mesenchymal Stem Cell Transplantation Has a Regenerative Effect in Ischemic Myocardium: An Experimental Rat Model Evaluated by SPECT-CT Assessment.Diagnostics (Basel, Switzerland) · 2024Article
- Non-invasive photoacoustic computed tomography of rat heart anatomy and function.Light, science & applications · 2023Article
- Development of a novel small-animal myocardial phantom can evaluate the image quality of dual-isotope simultaneous acquisition (DISA).Annals of nuclear medicine · 2022Article
- The frontier of live tissue imaging across space and time.Cell stem cell · 2021Review
- 3D Monte Carlo simulation of light distribution in mouse brain in quantitative photoacoustic computed tomography.Quantitative imaging in medicine and surgery · 2021Article
- Serial examination of cardiac function and perfusion in growing rats using SPECT/CT for small animals.Scientific reports · 2020Article
- Surgical and physiological challenges in the development of left and right heart failure in rat models.Heart failure reviews · 2019Review
- Prognostic Value of Early Evaluation of Left Ventricular Dyssynchrony After Myocardial Infarction.Molecular imaging and biology · 2019Article
- Quantification of Myocardial Perfusion Defect Size in Rats: Comparison between Quantitative Perfusion SPECT and Autoradiography.Molecular imaging and biology · 2018Article
- MRI with gadofosveset: A potential marker for permeability in myocardial infarction.Atherosclerosis · 2018Article
- Adaptation, Commissioning, and Evaluation of a 3D Treatment Planning System for High-Resolution Small-Animal Irradiation.Technology in cancer research & treatment · 2016Article
- Impact of injection dose, post-reconstruction filtering, and collimator choice on image quality of myocardial perfusion SPECT using cadmium-zinc telluride detectors in the rat.EJNMMI physics · 2015Article
- The role of preclinical SPECT in oncological and neurological research in combination with either CT or MRI.European journal of nuclear medicine and molecular imaging · 2014Review
- Comparison of 4D-microSPECT and microCT for murine cardiac function.Molecular imaging and biology · 2014Article
- Biodistribution and radiodosimetry of a novel myocardial perfusion tracer 123I-CMICE-013 in healthy rats.EJNMMI research · 2014Article
- Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs.Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologica · 2013Article
- Impact of a multiple mice holder on quantitation of high-throughput MicroPET imaging with and without Ct attenuation correction.Molecular imaging and biology · 2013Article
- Performance evaluation of small-animal multipinhole μSPECT scanners for mouse imaging.European journal of nuclear medicine and molecular imaging · 2013Article
- Effects of attenuation map accuracy on attenuation-corrected micro-SPECT images.EJNMMI research · 2013Article
- Myocardial infarct size and area at risk assessment in mice.Experimental and clinical cardiology · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.