Evidence map›Paper›PMID 20024624›Full record

ArticleAnnals of biomedical engineering2010

Falling-edge, variable threshold (FEVT) method for the automated detection of gastric slow wave events in high-resolution serosal electrode recordings.

Jonathan C Erickson, Gregory O'Grady, Peng Du, Chibuike Obioha, Wenlian Qiao, William O Richards, L Alan Bradshaw, Andrew J Pullan, Leo K Cheng

Abstract readEvaluation Study
In one paragraph

Article in Annals of biomedical engineering, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 50 papers.

0numbers the graph read from it
0cells of the map it votes in
50citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

50 citing papers in PubMed.

  1. Trial
  2. Simultaneous optical imaging of gastric slow waves and contractions in the in vivo porcine stomach.American journal of physiology. Gastrointestinal and liver physiology · 2024
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Time-Delay Mapping of High-Resolution Gastric Slow-Wave Activity.IEEE transactions on bio-medical engineering · 2017
    Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Characterization of Electrophysiological Propagation by Multichannel Sensors.IEEE transactions on bio-medical engineering · 2016
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jonathan C EricksonDepartment of Physics, Vanderbilt University, Nashville, TN, USA. ericksonj@wlu.edu
Gregory O'Grady
Peng Du
Chibuike Obioha
Wenlian Qiao
William O Richards
L Alan Bradshaw
Andrew J Pullan
Leo K Cheng

Funding

BIOMAGNETIC CHARACTERIZATION OF GASTRIC DYSRHYTHMIASR01DK058697 · NIDDK · VANDERBILT UNIVERSITY MEDICAL CENTER · PI BRADSHAW, LEONARD A · 2001 to 2013
$3.1M
Realistic models of gastrointestinal bioelectromagnetismR01DK064775 · NIDDK · VANDERBILT UNIVERSITY MEDICAL CENTER · PI CHENG, LEO · 2004 to 2014
$2.6M
Biomagnetic Signals of Intestinal IschemiaR01DK058197 · NIDDK · VANDERBILT UNIVERSITY · PI RICHARDS, WILLIAM O · 2002 to 2009
$2.6M
NIDDK NIH HHS R01 DK058197NIDDK NIH HHS R01 DK058697NIDDK NIH HHS R01 DK064775NIDDK NIH HHS R01 DK58197NIDDK NIH HHS R01 DK58697-02NIDDK NIH HHS R01 DK64775
6 · The paper itself

Abstract

High resolution (HR) multi-electrode mapping is increasingly being used to evaluate gastrointestinal slow wave behaviors. To create the HR activation time (AT) maps from gastric serosal electrode recordings that quantify slow wave propagation, it is first necessary to identify the AT of each individual slow wave event. Identifying these ATs has been a time consuming task, because there has previously been no reliable automated detection method. We have developed an automated AT detection method termed falling-edge, variable threshold (FEVT) detection. It computes a detection signal transform to accentuate the high 'energy' content of the falling edges in the serosal recording, and uses a running median estimator of the noise to set the time-varying detection threshold. The FEVT method was optimized, validated, and compared to other potential algorithms using in vivo HR recordings from a porcine model. FEVT properly detects ATs in a wide range of waveforms, making its performance substantially superior to the other methods, especially for low signal-to-noise ratio (SNR) recordings. The algorithm offered a substantial time savings (>100 times) over manual-marking whilst achieving a highly satisfactory sensitivity (0.92) and positive-prediction value (0.89).

Indexed as

AlgorithmsSignal Processing, Computer-AssistedAnimalsElectrodes, ImplantedElectromyographyMuscle, SmoothMyoelectric Complex, MigratingPattern Recognition, AutomatedStomachSwine

Identifiers

PMID20024624
PMCPMC2855965

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.