ArticleAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference2009
Active guidance for laser retinal surgery with a handheld instrument.
Article in Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 10 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
Abstract
Laser photocoagulation is a standard interventional tool in vitreoretinal surgery. Commonly applied treatments such as grid photocoagulation and panretinal photocoagulation involve the application of hundreds of dot-like laser burns to the retina. In order to enhance the accuracy and reduce the tedium of this procedure, we are developing a robot-assisted technique for retinal laser photocoagulation that includes software for planning patterns of laser burns on a retinal image and uses an active handheld micromanipulator known as Micron in order to apply the pattern of burns to the retina. The paper describes the system and presents preliminary results. In a sample 7x7 pattern of lesions applied to an artificial surface, the system demonstrated a mean position error of 43+/-23 microm.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.