Evidence map›Paper›PMID 19926464›Full record

ArticleBiosensors & bioelectronics2010

Enhancing the longevity of microparticle-based glucose sensors towards 1 month continuous operation.

Saurabh Singh, Mike McShane

Abstract readEvaluation Study
In one paragraph

Article in Biosensors & bioelectronics, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
4.9field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 35 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Enzymatic Glucose Sensor Compensation for Variations in Ambient Oxygen Concentration.Proceedings of SPIE--the International Society for Optical Engineering · 2015
    Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Saurabh SinghDepartment of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
Mike McShane
Texas A&M University · US

Funding

Fluorescent Glucose Sensors from Polyion MicroshellsR01EB000739 · NIBIB · TEXAS ENGINEERING EXPERIMENT STATION · PI MCSHANE, MIKE · 2002 to 2006
$1.3M
NIBIB NIH HHS R01 EB000739
6 · The paper itself

Abstract

Luminescent microspheres encapsulating glucose oxidase have recently been reported as potential implantable sensors, but the operational lifetime of these systems has been limited by enzyme degradation. We report here that the longevity of these enzymatic microparticle-based sensors has been extended by the coimmobilization of glucose oxidase (GOx) and catalase (CAT) into the sensor matrix. A mathematical model was used to compare the response and longevity of the sensors with and without catalase. To experimentally test the longevity, sensors were continuously operated under normoglycemic dermal substrate concentrations and physiological conditions (5.5 mM glucose and 140 microM O(2), 37 degrees C and pH 7.4). The sensors incorporating CAT were experimentally shown to be approximately 5 times more stable than those without CAT; nevertheless, the response of sensors with CAT still changed by approximately 20%, when operated continuously for 7 days. The experimentally determined trends obtained for the variation in sensor response due to enzyme deactivation were in close agreement with modeling predictions, which also revealed a significant apparent loss in enzyme activity upon immobilization. It was further predicted via modeling that by incorporating 0.1 mM each of active GOx and CAT, the sensors will exhibit less than 2% variation in response over 1 month of continuous operation.

Indexed as

Models, ChemicalBiosensing TechniquesCatalaseComputer-Aided DesignComputer SimulationEquipment DesignEquipment Failure AnalysisGlucoseGlucose OxidaseLuminescent MeasurementsMicrospheresReproducibility of ResultsSensitivity and SpecificityCatalaseGlucoseGlucose Oxidase

Identifiers

PMID19926464
PMCPMC2818267
OpenAlexW1964611095

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.