Evidence map›Paper›PMID 19894087›Full record

ReviewJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2009

Recent progress in mechanical artificial pancreas.

Masami Hoshino, Yoshikura Haraguchi, Iwanori Mizushima, Motohiro Sakai

Abstract readReview
PubMed Publisher
In one paragraph

Review in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 23 citations in OpenAlex.

  1. Effects of electrical microstimulation of peripheral sympathetic nervous fascicle on glucose uptake in rats.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2013
    Article
  2. Wearable and implantable pancreas substitutes.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2013
    Review
  3. Review
  4. Article
  5. Atomic layer deposition-based functionalization of materials for medical and environmental health applications.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2010
    Article
  6. Journal of Artificial Organs 2009: the year in review.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2010
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Masami HoshinoDepartment of Surgery, Shisei Hospital, Sayama-shi, Saitama, Japan. noel2000@aioros.ocn.ne.jp
Yoshikura Haraguchi
Iwanori Mizushima
Motohiro Sakai
Kensei Hospital · JPNational Hospital Organization · JPTokyo Women's Medical University Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Strict blood glucose (BG) control is proved to improve the outcome in patients with glucose intolerance both in acute and chronic phases, irrespective of whether the patient has diabetes mellitus. However, strict BG control by conventional methods is so complicated that it cannot be performed easily in normal clinical situations. Furthermore, it is sometimes inadequate. Therefore, a clinically applicable, reliable artificial pancreas (AP) has long been sought after for more than 40 years. Considering the present important situations concerning AP, a survey of recent progress in AP is highly desirable. In this review, recent progress in mechanical AP (MAP) and in MAP-related items is presented. MAP is composed of three major components: a BG control algorithm, a drug administration system, and a glucose sensor. Recent progress in development of these components is presented, followed by descriptions of representative MAPs. Although significant progress in the development of MAP has been made, its use in clinical situations is limited or for research purposes at present. The main limiting factor is the slow progress in the development of glucose sensors. However, more widespread clinical application of the MAP will occur in the near future, considering the number of reliable long-life intravenous glucose sensors under development. Another factor is the worldwide recognition of the importance of BG control in acutely ill patients, in whom the period of strict BG control is usually for several days to a few weeks.

Indexed as

Pancreas, ArtificialBlood GlucoseDiabetes MellitusGlucose IntoleranceHumansHypoglycemic AgentsInsulin Infusion SystemsBlood GlucoseHypoglycemic Agents

Identifiers

PMID19894087
OpenAlexW1970523855

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked