Evidence map›Paper›PMID 19889206›Full record

Trial reportJournal of cardiothoracic surgery2009

Efficacy of TachoSil patches in controlling Dacron suture-hole bleeding after abdominal aortic aneurysm open repair.

Guido Bajardi, Felice Pecoraro, Domenico Mirabella

Open access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Journal of cardiothoracic surgery, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 3 pooled it
1.2field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 3 syntheses or guidelines pooled it, 29 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Trial
  5. Could TachoSil application in cardiac surgery be potentially dangerous? A review of the literature.Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery · 2025
    Review
  6. Electrospun PCL-Based Vascular Grafts: In Vitro Tests.Nanomaterials (Basel, Switzerland) · 2021
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Guido BajardiVascular Surgery Unit - University of Palermo, 90100 Palermo, Italy. guidobajardi@libero.it
Felice Pecoraro
Domenico Mirabella
University of Palermo · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study is evaluate the efficacy of TachoSil patches in controlling suture-hole bleeding after elective infrarenal abdominal aortic aneurysm (AAA) replacement with Dacron graft. MATERIALS AND

methodsPatients undergoing elective replacement of infrarenal AAA with Dacron grafts were prospectively randomized to TachoSil patches (Group I) or standard compression with surgical swabs (Group II).We evaluated time to haemostasis, blood loss during the operation, blood loss after cross-clamp removal, duration of operation, drain volume, requirement for blood transfusion and surgeons rating of efficacy.

resultsTwenty patients were randomized (10 patients in each treatment Group). The mean time to haemostasis was 264 +/- 127.1 s (range: 180-600 s) in Group I and 408 +/- 159.5 s (range: 120-720 s) in Group II (p = 0.026); mean blood loss during the operation was 503.5 +/- 20.7 cc (range: 474-545 cc) in Group I and 615.7 +/- 60.3 cc (range: 530-720 cc) in Group II (p < 0.001); mean blood loss after cross-clamp removal was 26.5 +/- 4 g (range: 22-34 g) in Group I and 45.4 +/- 4.6 (range: 38-52 g) in Group II (p < 0.001) and mean drain volume was 116.7 +/- 41.4 cc (range: 79-230 cc) in Group I and 134.5 +/- 42.8 cc (range: 101-250 cc) in Group II (p = 0.034). There were no serious adverse events associated with use of TachoSil patches.

conclusionFor patients undergoing aortic reconstruction with Dacron grafts, TachoSil patches were found to be safe and effective for the control of suture-hole bleeding.

Indexed as

AgedAged, 80 and overAortic Aneurysm, AbdominalBlood Loss, SurgicalBlood Vessel Prosthesis ImplantationDrug CombinationsFemaleFibrinogenHemostaticsHumansMaleMiddle AgedProspective StudiesSuturesThrombinTreatment OutcomeDrug CombinationsFibrinogenHemostaticsTachoSilThrombin

Identifiers

PMID19889206
PMCPMC2776591
OpenAlexW2161572158

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.