ArticleJournal of diabetes science and technology2008

Evaluation of the VIA Blood Chemistry Monitor for Glucose in Healthy and Diabetic Volunteers.

Arjunan Ganesh, Brian Hipszer, Navdeep Loomba, Barbara Simon, Marc C Torjman, Jeffrey Joseph

Open access · bronzeAbstract read
In one paragraph

Article in Journal of diabetes science and technology, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.2field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 15 citations in OpenAlex.

  1. Trial
  2. Review
  3. Glucose Management Technologies for the Critically Ill.Journal of diabetes science and technology · 2019
    Review
  4. Observational
  5. Review
  6. Why Have So Many Intravascular Glucose Monitoring Devices Failed?Journal of diabetes science and technology · 2015
    Review
  7. Article
  8. Clinical need for continuous glucose monitoring in the hospital.Journal of diabetes science and technology · 2009
    Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 1 country.

Arjunan GaneshThe Children's Hospital of Philadelphia and University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania, USA.
Brian Hipszer
Navdeep Loomba
Barbara Simon
Marc C Torjman
Jeffrey Joseph
Thomas Jefferson University · USChildren's Hospital of Philadelphia · USCooper University Hospital · USDrexel University · USPain Management Institute · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundManual methods of blood glucose monitoring are labor-intensive, costly, prone to error, and expose the caregiver to blood. The VIA(R) blood chemistry monitor for glucose can automatically measure plasma glucose (PG) every 5 minutes for 72 hours using blood sampled from a peripheral vein/artery or a central vein.

methodsVIA performance was evaluated in eight normal and five type 1 diabetic (T1DM) subjects in 15 separate experiments. The VIA device was connected to a peripheral vein and reported a PG value every 5 minutes during each 510-minute experiment. Blood samples were collected manually every 10 minutes and assayed using a HemoCue(R) beta-glucose analyzer (HC). Whole blood HC measurements were corrected to PG values. Paired HC/VIA measurements (n = 717) were analyzed.

resultsMean PG was 90 +/- 14 and 96 +/- 12 mg/dl in normal subjects and 194 +/- 64 and 173 +/- 48 mg/dl in T1DM subject as measured by the HC and VIA, respectively. Clark error grid analysis revealed 86% points in zone A, 11% points in zone B, and 2% points in zone D. Linear regression analysis yielded the following equation: VIA = 0.732 x HC + 30.5 (r(2) = 0.954). Residual analysis revealed a glucose-dependent bias between the HC and the VIA. VIA data were transformed using the linear regression equation to correct for bias. After the correction, the mean absolute relative difference between the VIA and the HC was less than 10%, and 99.6% of data were in zones A and B. The VIA was able to sample blood automatically every 5 minutes for more than 8 hours in the laboratory setting. On average, the VIA reported glucose values for 94% of the samples it attempted to obtain.

conclusionsThis study demonstrated that the VIA blood chemistry monitor for glucose can reliably sample blood frequently for a prolonged period of time safely and effectively in diabetic and nondiabetic volunteers. Agreement between the two devices was the closest at normal glucose concentrations. After correcting for a glucose-dependent bias between the devices, the MARD was consistently less than 10% for all glucose ranges.

Indexed as

CGMcontinuous glucose monitoring systemglucose sensorV-GLU1 glucose sensorVIA blood chemistry monitor for glucoseVIA glucose monitoring system

Identifiers

PMID19885341
PMCPMC2771480
OpenAlexW2237523353

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.