ArticleJournal of diabetes science and technology2008
Development of novel glucose sensing fluids with potential application to microelectromechanical systems-based continuous glucose monitoring.
Article in Journal of diabetes science and technology, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications.Sensors (Basel, Switzerland) · 2019Article
- A dielectric affinity glucose microsensor using hydrogel-functionalized coplanar electrodes.Microfluidics and nanofluidics · 2017Article
- A hydrogel-based glucose affinity microsensor.Sensors and actuators. B, Chemical · 2016Article
- A MEMS Dielectric Affinity Glucose Biosensor.Journal of microelectromechanical systems : a joint IEEE and ASME publication on microstructures, microactuators, microsensors, and microsystems · 2013Article
- Synthesis and development of poly(N-hydroxyethyl acrylamide)-ran-3-acrylamidophenylboronic acid polymer fluid for potential application in affinity sensing of glucose.Journal of diabetes science and technology · 2011Article
- A Capacitive MEMS Viscometric Sensor for Affinity Detection of Glucose.Journal of microelectromechanical systems : a joint IEEE and ASME publication on microstructures, microactuators, microsensors, and microsystems · 2009Article
- A MEMS affinity glucose sensor using a biocompatible glucose-responsive polymer.Sensors and actuators. B, Chemical · 2009Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWe have previously presented a microelectromechanical systems (MEMS) viscometric sensor for continuous glucose monitoring. The sensing fluid used therein was based on protein concanavalin A, which is known to have significant drawbacks, such as immunotoxicity and instability. To address this issue, a stable, biocompatible polymeric sensing fluid has been developed.
methodsIn the polymeric sensing system, glucose reversibly formed strong ester bonds with the phenylboronic acid moiety on the poly(acrylamide-ran-3-acrylamidophenylboronic acid) (PAA-ran-PAAPBA) polymer backbone, resulting in cross-linking of the copolymers and an increase in the solution viscosity. The copolymers were synthesized via classic free radical copolymerization processes. The viscosity of the PAA-ran-PAAPBA, dissolved in phosphate-buffered saline buffer and in the presence of glucose at physiologically relevant concentrations, was measured by an Ubbelodhe viscometer and a prototype MEMS viscometric device.
resultsExperimental results showed that the polymer molecular weight and composition depended on the solvent quantity, while the sensing fluid viscosity was determined by the polymer molecular weight and percentage composition of PAAPBA. The study of the temperature effect on viscosity showed that the polymer sensed glucose effectively under physiological conditions, although the high temperature lowered its sensitivity. Through proper adjustment of these parameters, a distinctive viscosity increase was observed when the glucose concentration increased from 0 to 450 mg/dl, which was detectable by our prototype MEMS device.
conclusionsWe have successfully developed a stable, biocompatible polymeric system for the sensitive detection of glucose. MEMS experiments demonstrated that the sensing fluid was able to sense glucose at different concentrations. This sensing system can potentially enable highly reliable, continuous monitoring of glucose in interstitial fluid from subcutaneous tissue.