ArticleJournal of diabetes science and technology2007
Blood-induced interference of glucose sensor function in vitro: implications for in vivo sensor function.
Article in Journal of diabetes science and technology, 2007. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 14 citations in OpenAlex.
- Redundancy in Glucose Sensing: Enhanced Accuracy and Reliability of an Electrochemical Redundant Sensor for Continuous Glucose Monitoring.Journal of diabetes science and technology · 2016Trial
- Studies of combined NO-eluting/CD47-modified polyurethane surfaces for synergistic enhancement of biocompatibility.Colloids and surfaces. B, Biointerfaces · 2020Article
- Nanotechnology in cell replacement therapies for type 1 diabetes.Advanced drug delivery reviews · 2019Review
- Macrophage embedded fibrin gels: an in vitro platform for assessing inflammation effects on implantable glucose sensors.Biomaterials · 2014Article
- Cell based metabolic barriers to glucose diffusion: macrophages and continuous glucose monitoring.Biomaterials · 2014Article
- Predicting glucose sensor behavior in blood using transport modeling: relative impacts of protein biofouling and cellular metabolic effects.Journal of diabetes science and technology · 2013Article
- Role of interleukin-1/interleukin-1 receptor antagonist family of cytokines in long-term continuous glucose monitoring in vivo.Journal of diabetes science and technology · 2013Article
- Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.Journal of diabetes science and technology · 2011Review
- Metabolic biofouling of glucose sensors in vivo: role of tissue microhemorrhages.Journal of diabetes science and technology · 2011Article
- Analyte flux at a biomaterial-tissue interface over time: implications for sensors for type 1 and 2 diabetes mellitus.Journal of diabetes science and technology · 2010Article
- Importance of interleukin-1 and interleukin-1 receptor antagonist in short-term glucose sensor function in vivo.Journal of diabetes science and technology · 2010Article
- The benefits of implanted glucose sensors.Journal of diabetes science and technology · 2007Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAlthough tissue hemorrhages, with resulting blood clots, are associated with glucose sensor implantation, virtually nothing known is about the impact of red blood cells and red blood cell clots on sensor function in vitro or in vivo. In these studies, we tested the hypothesis that blood can directly interfere with glucose sensor function in vitro.
methodsTo test this hypothesis, heparinized human whole blood (HWB) and nonheparinized human whole blood (WB) were obtained from normal individuals. Aliquots of HWB and WB samples were also fractionated into plasma, serum, and total leukocyte (TL) components. Resulting HWB, WB, and WB components were incubated in vitro with an amperometric glucose sensor for 24 hours at 37 degrees C. During incubation, blood glucose levels were determined periodically using a glucose monitor, and glucose sensor function (GSF) was monitored continuously as nanoampere output.
resultsHeparinized human whole blood had no significant effect on GSF in vitro, nor did TL, serum, or plasmaderived clots from WB. Sensors incubated with WB displayed a rapid signal loss associated with clot formation at 37 degrees C. The half-life was 0.8 +/- 0.2 hours (n = 16) for sensors incubated with WB compared to 3.2 +/- 0.5 (n = 12) for sensors incubated with HWB with a blood glucose level of approximately 100 mg/dl.
conclusionsThese studies demonstrated that human whole blood interfered with GSF in vitro. These studies further demonstrated that this interference was related to blood clot formation, as HWB, serum, plasma-derived clots, or TL did not interfere with GSF in vitro in the same way that WB did. These in vitro studies supported the concept that the formation of blood clots at sites of glucose sensor implantation could have a negative impact on GSF in vivo.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials