Dynamic contrast-enhanced diffuse optical tomography (DCE-DOT): experimental validation with a dynamic phantom.

Mehmet Burcin Unlu, Yuting Lin, Gultekin Gulsen

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Dual-contrast dynamic MRI-DOT for small animal imaging.Technology in cancer research & treatment · 2010
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mehmet Burcin UnluTu and Yuen Center for Functional Onco Imaging, University of California, Irvine, CA 92617, USA.
Yuting Lin
Gultekin Gulsen

Funding

SPATIAL /SPECTRAL TOMOGRAPHY FOR FUNCTIONAL SPECTROSCOPYU54CA105480 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI TROMBERG, BRUCE J · 2003 to 2007
$6.6M
Development of A Multi-Modality System for Onco-ImagingR33CA120175 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI GULSEN, GULTEKIN · 2008 to 2010
$1.5M
Tomographic Molecular Imaging for Breast CancerR01EB008716 · NIBIB · UNIVERSITY OF CALIFORNIA-IRVINE · PI GULSEN, GULTEKIN · 2008 to 2011
$1.3M
COMBINED MR-DIFFUSE OPTICS FOR FUNCTIONAL IMAGINGR33CA101139 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI NALCIOGLU, ORHAN · 2005 to 2007
$1.3M
Combined MRI and Optical Imaging to Improved Breast Cancer DiagnosisR21CA121568 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI SU, MIN-YING L. · 2007 to 2008
$580k
Development of A Multi-Modality System for Onco-ImagingR21CA120175 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI GULSEN, GULTEKIN · 2007 to 2007
$225k
COMBINED MR-DIFFUSE OPTICS FOR FUNCTIONAL IMAGINGR21CA101139 · NCI · UNIVERSITY OF CALIFORNIA IRVINE · PI NALCIOGLU, ORHAN · 2004 to 2004
$157k
NCI NIH HHS R21/33 CA-101139NCI NIH HHS R21/33 CA 120175NCI NIH HHS R21 CA101139NCI NIH HHS R21 CA 121568NCI NIH HHS R21 CA121568NCI NIH HHS R33 CA101139NCI NIH HHS R33 CA120175NCI NIH HHS U54 CA 105480NCI NIH HHS U54 CA105480NIBIB NIH HHS R01 EB 008716NIBIB NIH HHS R01 EB008716
6 · The paper itself

Abstract

Dynamic contrast-enhanced diffuse optical tomography (DCE-DOT) can provide spatially resolved enhancement kinetics of an optical contrast agent. We undertook a systematic phantom study to evaluate the effects of the geometrical parameters such as the depth and size of the inclusion as well as the optical parameters of the background on the recovered enhancement kinetics of the most commonly used optical contrast agent, indocyanine green (ICG). For this purpose a computer-controlled dynamic phantom was constructed. An ICG-intralipid-water mixture was circulated through the inclusions while the DCE-DOT measurements were acquired with a temporal resolution of 16 s. The same dynamic study was repeated using inclusions of different sizes located at different depths. In addition to this, the effect of non-scattering regions was investigated by placing a second inclusion filled with water in the background. The phantom studies confirmed that although the peak enhancement varied substantially for each case, the recovered injection and dilution rates obtained from the percentage enhancement maps agreed within 15% independent of not only the depth and the size of the inclusion but also the presence of a non-scattering region in the background. Although no internal structural information was used in these phantom studies, it may be necessary to use it for small objects buried deep in tissue. However, the different contrast mechanisms of optical and other imaging modalities as well as imperfect co-registration between both modalities may lead to potential errors in the structural a priori. Therefore, the effect of erroneous selection of structural priors was investigated as the final step. Again, the injection and dilution rates obtained from the percentage enhancement maps were also immune to the systematic errors introduced by erroneous selection of the structural priors, e.g. choosing the diameter of the inclusion 20% smaller increased the peak enhancement 60% but changed the injection and dilution rates only less than 10%.

Indexed as

Phantoms, ImagingAlgorithmsAnimalsContrast MediaEquipment DesignHumansImage Interpretation, Computer-AssistedIndocyanine GreenKineticsModels, StatisticalScattering, RadiationTime FactorsTomography, OpticalContrast MediaIndocyanine Green

Identifiers

PMID19841515
PMCPMC3919674

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.