Dual resolution cone beam breast CT: a feasibility study.

Lingyun Chen, Youtao Shen, Chao-Jen Lai, Tao Han, Yuncheng Zhong, Shuaiping Ge, Xinming Liu, Tianpeng Wang, Wei T Yang, Gary J Whitman and 1 more

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 30 citations in OpenAlex.

  1. Clinical Micro-CT Empowered by Interior Tomography, Robotic Scanning, and Deep Learning.IEEE access : practical innovations, open solutions · 2020
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Lingyun ChenDepartment of Imaging Physics, University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030-4009, USA. lingyun.chen@di.mdacc.tmc.edu
Youtao Shen
Chao-Jen Lai
Tao Han
Yuncheng Zhong
Shuaiping Ge
Xinming Liu
Tianpeng Wang
Wei T Yang
Gary J Whitman
Chris C Shaw
The University of Texas MD Anderson Cancer Center · US

Funding

aSi/CsI FP digital chest imaging with scatter rejectionR01EB000117 · NIBIB · UNIVERSITY OF TEXAS MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2002 to 2005
$2.3M
Optimized Digital Mammography with an a-Se FP ImagerR01CA104759 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2004 to 2007
$2.2M
A Dual Resolution Cone Beam CT System for 3-D Breast ImagingR33CA124585 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2008 to 2010
$1.3M
A Dual Resolution Cone Beam CT System for 3-D Breast ImagingR21CA124585 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2007 to 2007
$234k
NCI NIH HHS CA104759NCI NIH HHS CA124585NCI NIH HHS R01 CA104759NCI NIH HHS R21 CA124585NCI NIH HHS R33 CA124585NIBIB NIH HHS EB000117NIBIB NIH HHS R01 EB000117
6 · The paper itself

Abstract

purposeIn this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction.

methodsWith this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 microm and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package.

resultsThe results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan.

conclusionsThese results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.

Indexed as

AlgorithmsBreastBreast NeoplasmsCalcinosisComputer SimulationCone-Beam Computed TomographyFeasibility StudiesFemaleHumansImaging, Three-DimensionalMammographyMonte Carlo MethodParaffinPhantoms, ImagingRadiation DosageScattering, RadiationParaffin

Identifiers

PMID19810473
PMCPMC2738741
OpenAlexW2088280998

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.