Evidence map›Paper›PMID 19789213›Full record

ArticleEvidence-based complementary and alternative medicine : eCAM2011

A clinical study of the pulse wave characteristics at the three pulse diagnosis positions of chon, gwan and cheok.

Young J Jeon, Jaeuk U Kim, Hae J Lee, Jeon Lee, Hyun H Ryu, Yu J Lee, Jong Y Kim

Abstract read
In one paragraph

Article in Evidence-based complementary and alternative medicine : eCAM, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry.Evidence-based complementary and alternative medicine : eCAM · 2018
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Development of pulse diagnostic devices in Korea.Integrative medicine research · 2013
    Review
  13. Article
  14. Three-dimensional motion of the radial artery and the spatiality, rhythmicity, formability and intensity of TCM pulse diagnosis.African journal of traditional, complementary, and alternative medicines : AJTCAM · 2013
    Article
  15. New assessment model of pulse depth based on sensor displacement in pulse diagnostic devices.Evidence-based complementary and alternative medicine : eCAM · 2013
    Article
  16. Novel diagnostic model for the deficient and excess pulse qualities.Evidence-based complementary and alternative medicine : eCAM · 2012
    Article
  17. Temporal and spatial properties of arterial pulsation measurement using pressure sensor array.Evidence-based complementary and alternative medicine : eCAM · 2012
    Article
  18. Radial pressure pulse and heart rate variability in heat- and cold-stressed humans.Evidence-based complementary and alternative medicine : eCAM · 2011
    Article
  19. Article
  20. Novel diagnostic algorithm for the floating and sunken pulse qualities and its clinical test.Evidence-based complementary and alternative medicine : eCAM · 2011
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Young J JeonConstitutional Biology and Medical Engineering Research Center, Korea Institute of Oriental Medicine (KIOM), 461-24 Jeonmin-dong, Yuseong-gu, Daejeon 305-811, Republic of Korea.
Jaeuk U Kim
Hae J Lee
Jeon Lee
Hyun H Ryu
Yu J Lee
Jong Y Kim

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this work, we analyze the baseline, signal strength, aortic augmentation index (AIx), radial AIx, time to reflection and P_T2 at Chon, Gwan, and Cheok, which are the three pulse diagnosis positions in Oriental medicine. For the pulse measurement, we used the SphygmoCor apparatus, which has been widely used for the evaluation of the arterial stiffness at the aorta. By two-way repeated measures analysis of variance, we tested two independent measurements for repeatability and investigated their mean differences among Chon, Gwan and Cheok. To characterize further the parameters that were shown to be different between each palpation position, we carried out Duncan's test for the multiple comparisons. The baseline and signal strength were statistically different (P < .05) among Chon, Gwan and Cheok, respectively, which supports the major hypothesis of Oriental medicine that all of the three palpation positions contain different clinical information. On the other hand, aortic AIx and time to reflection were found to be statistically different between Chon and the others, and radial AIx and P_T2 did not show any difference between pulse positions. In the clinical sense, however, the aortic AIx at each palpation position was found to fall within the 90% confidence interval of normal arterial compliance. The results of the multiple comparisons indicate that the parameters of arterial stiffness were independent of the palpation positions. This work is the first attempt to characterize quantitatively the pulse signals at Chon, Gwan and Cheok with some relevant parameters extracted from the SphygmoCor apparatus.

Identifiers

PMID19789213
PMCPMC3137784

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.