ReviewWorld journal of gastroenterology2009
What is artificial endocrine pancreas? Mechanism and history.
Review in World journal of gastroenterology, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Precision and accuracy of hyperglycemic clamps in a multicenter study.American journal of physiology. Endocrinology and metabolism · 2021Trial
- Ultra-Rapid Lispro results in accelerated insulin lispro absorption and faster early insulin action in comparison with HumalogJournal of diabetes investigation · 2020Trial
- A non-inferiority study to compare daily fast-acting insulin versus twice a week slow-acting insulin-moderate diabetes mode.Acta cirurgica brasileira · 2020Article
- The Discovery of Insulin: An Important Milestone in the History of Medicine.Frontiers in endocrinology · 2018Review
- Glucose Sensing for Diabetes Monitoring: Recent Developments.Sensors (Basel, Switzerland) · 2017Review
- Twenty-first century: the beginning of the replacement parts era?Sao Paulo medical journal = Revista paulista de medicina · 2012Article
- Progressive artificial endocrine pancreas: The era of novel perioperative blood glucose control for surgery.Surgery today · 2011Review
- Closed-loop insulin delivery: from bench to clinical practice.Nature reviews. Endocrinology · 2011Review
- In silico evaluation of a control system and algorithm for automated insulin infusion in the ICU setting.Biomedical engineering online · 2010Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The artificial endocrine pancreas is a feedback control instrument that regulates insulin delivery on a minute-by-minute basis according to measured blood glucose levels. Only one type of bedside-type artificial endocrine pancreas is now available in Japan: STG-22 (Nikkiso Co. Ltd., Japan). In the insulin infusion algorithm, insulin is infused on the basis of its proportional and derivative actions, to blood glucose concentrations with a constant time delay. The bedside-type artificial endocrine pancreas has been proven to be useful not only as a therapeutic tool for diabetes mellitus, but also as an elegant research tool for investigating the pathophysiology of the disease, by using the euglycemic hyperinsulinemic glucose clamp technique. The wearable type of closed-loop system has been developed recently. The breakthrough is the establishment of a needle-type glucose sensor. The development of closed-loop glycemic control systems that enable long-term physiological regulation has focused on implantable devices. Much effort has been expended to realize these devices.