ReviewDer Anaesthesist2009
[Haemodynamic monitoring in the perioperative phase. Available systems, practical application and clinical data].
Review in Der Anaesthesist, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- [Perioperative fluid management in major abdominal surgery].Der Anaesthesist · 2021Review
- [Hemodynamic monitoring in intensive care and emergency medicine : Integration of clinical signs and ultrasound findings].Medizinische Klinik, Intensivmedizin und Notfallmedizin · 2016Review
- [Volume replacement in intensive care medicine].Der Anaesthesist · 2011Review
- [How should anesthesiologists perform ultrasound examinations? Diagnostic use of ultrasound in emergency and intensive care and medicine].Der Anaesthesist · 2011Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A regular hydration status and compensated vascular filling are targets of perioperative fluid and volume management and, in parallel, represent precautions for sufficient stroke volume and cardiac output to maintain tissue oxygenation. The physiological and pathophysiological effects of fluid and volume replacement mainly depend on the pharmacological properties of the solutions used, the magnitude of the applied volume as well as the timing of volume replacement during surgery. In the perioperative setting surgical stress induces physiological and hormonal adaptations of the body, which in conjunction with an increased permeability of the vascular endothelial layer influence fluid and volume management. The target of haemodynamic monitoring in the operation room is to collect data on haemodynamics and global oxygen transport, which enable the anaesthetist to estimate the volume status of the vascular system. Particularly in high risk patients this may improve fluid and volume therapy with respect to maintaining cardiac output. A goal-directed volume management aiming at preventing hypovolaemia may improve the outcome after surgery. The objective of this article is to review the monitoring devices that are currently used to assess haemodynamics and filling status in the perioperative setting. Methods and principles for measuring haemodynamic variables, the measured and calculated parameters as well as clinical benefits and shortcomings of each device are described. Furthermore, the results for monitoring devices from clinical studies of goal-directed fluid and volume therapy which have been published will be discussed.
Indexed as
Identifiers
19669105What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.