ArticleThe open biomedical engineering journal2008
Neither a nitric oxide donor nor potassium channel blockage inhibit RBC mechanical damage induced by a roller pump.
Article in The open biomedical engineering journal, 2008. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 6 citations in OpenAlex.
- Reduced lifespan of erythrocytes in Dahl/Salt sensitive rats is the cause of the renal proximal tubule damage.Scientific reports · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 2 countries.
Funding
Abstract
Red blood cells (RBC) are exposed to various levels of shear stresses when they are exposed to artificial flow environments, such as extracorporeal flow circuits and hemodialysis equipment. This mechanical trauma affects RBC and the resulting effect is determined by the magnitude of shear forces and exposure time. It has been previously demonstrated that nitric oxide (NO) donors and potassium channel blockers could prevent the sub-hemolytic damage to RBC, when they are exposed to 120 Pa shear stress in a Couette shearing system. This study aimed at testing the effectiveness of NO donor sodium nitroprussid (SNP, 10⁻⁴ M) and non-specific potassium channel blocker tetraethylammonium (TEA, 10⁻⁷ M) in preventing the mechanical damage to RBC in a simple flow system including a roller pump and a glass capillary of 0.12 cm diameter. RBC suspensions were pumped through the capillary by the roller pump at a flow rate that maintains 200 mmHg hydrostatic pressure at the entrance of the capillary. An aliquot of 10 ml of RBC suspension of 0.4 L/L hematocrit was re-circulated through the capillary for 30 minutes. Plasma hemoglobin concentrations were found to be significantly increased (~7 folds compared to control aliquot which was not pumped through the system) and neither SNP nor TEA prevented this hemolysis. Alternatively, RBC deformability assessed by laser diffraction ektacytometry was not altered after 30 min of pumping and both SNP and TEA had no effect on this parameter. The results of this study indicated that, in contrast with the findings in RBC exposed to a well-defined magnitude of shear stress in a Couette shearing system, the mechanical damage induced by a roller pump could not be prevented by NO donor or potassium channel blocker.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.