Trial reportThe Journal of bone and joint surgery. American volume2009
Range of motion of standard and high-flexion posterior cruciate-retaining total knee prostheses a prospective randomized study.
Trial report in The Journal of bone and joint surgery. American volume, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 1 synthesis or guideline pooled it, 60 citations in OpenAlex.
- Comparison of High-Flexion and Conventional Implants in Total Knee Arthroplasty: A Meta-Analysis.Medical science monitor : international medical journal of experimental and clinical research · 2015Pooled it
- Do tibiofemoral contact point and posterior condylar offset influence outcome and range of motion in a mobile-bearing total knee arthroplasty?Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2014Trial
- Do patients care about higher flexion in total knee arthroplasty? A randomized, controlled, double-blinded trial.BMC musculoskeletal disorders · 2013Trial
- Using deep networks for knee range of motion monitoring in total knee arthroplasty rehabilitation.Frontiers in bioengineering and biotechnology · 2025Article
- No difference of survival between cruciate retaining and substitution designs in high flexion total knee arthroplasty.Scientific reports · 2021Article
- Simplified Chinese version of the Forgotten Joint Score (FJS) for patients who underwent joint arthroplasty: cross-cultural adaptation and validation.Journal of orthopaedic surgery and research · 2017Article
- Good validity and reliability of the forgotten joint score in evaluating the outcome of total knee arthroplasty.Acta orthopaedica · 2016Article
- Does knee awareness differ between different knee arthroplasty prostheses? A matched, case-control, cross-sectional study.BMC musculoskeletal disorders · 2016Article
- Preservation of the PCL when performing cruciate-retaining TKA: Is the tibial tuberosity a reliable predictor of the PCL footprint location?Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2016Article
- In vivo length change patterns of the medial and lateral collateral ligaments along the flexion path of the knee.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2015Article
- Patients achieved greater range of movement when using high-flexion implants.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2015Review
- Fibula head is a useful landmark to predict the location of posterior cruciate ligament footprint prior to total knee arthroplasty.International orthopaedics · 2014Article
- How much of the PCL is really preserved during the tibial cut?Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2012Article
- The Columbus Knee System: 4-Year Results of a New Deep Flexion Design Compared to the NexGen Full Flex Implant.Arthritis · 2012Article
- Can a high-flexion total knee arthroplasty relieve pain and restore function without premature failure?Clinical orthopaedics and related research · 2012Article
- High-flexion total knee arthroplasty improves flexion of stiff knees.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2011Article
- Current surgical treatment of knee osteoarthritis.Arthritis · 2011Article
Corrections and comments
- Commented on by
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe main goals of total knee arthroplasty are pain relief and improvement in function and the range of motion. The purpose of this study was to compare the ranges of motion of the knees of patients treated with a standard posterior cruciate-retaining total knee prosthesis in one knee and a high-flexion posterior cruciate-retaining total knee prosthesis in the other.
methodsFifty-four patients (mean age, 69.7 years) received a standard posterior cruciate-retaining total knee prosthesis in one knee and a high-flexion posterior cruciate-retaining total knee prosthesis in the contralateral knee. Five patients were men, and forty-nine were women. At a mean of three years postoperatively, the patients were assessed clinically and radiographically with the knee-rating systems of the Knee Society and the Hospital for Special Surgery and with the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score.
resultsThe mean postoperative Knee Society and Hospital for Special Surgery knee scores were 93.7 and 89 points, respectively, for the knees with a standard posterior cruciate-retaining prosthesis, and they were 93.9 and 90 points, respectively, for the knees with a high-flexion posterior cruciate-retaining prosthesis. The mean postoperative WOMAC score was 22 points. Postoperatively, the mean ranges of motion without and with weight-bearing were 131 degrees (range, 90 degrees to 150 degrees) and 115 degrees (range, 75 degrees to 145 degrees), respectively, in the knees with a standard prosthesis and 133 degrees (range, 90 degrees to 150 degrees) and 118 degrees (range, 75 degrees to 145 degrees), respectively, in those with a high-flexion prosthesis. Patient satisfaction and radiographic results were similar in the two groups. No knee had aseptic loosening, revision, or osteolysis.
conclusionsAfter a minimum duration of follow-up of three years, we found no significant differences between the two groups with regard to the range of knee motion or the clinical or radiographic parameters.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials