Improving FAIMS sensitivity using a planar geometry with slit interfaces.
Article in Journal of the American Society for Mass Spectrometry, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Performance Enhancements in Differential Ion Mobility Spectrometry-Mass Spectrometry (DMS-MS) by Using a Modified CaptiveSpray Source.Journal of the American Society for Mass Spectrometry · 2018Article
- Article
- Review on ion mobility spectrometry. Part 1: current instrumentation.The Analyst · 2015Review
- On an aerodynamic mechanism to enhance ion transmission and sensitivity of FAIMS for nano-electrospray ionization-mass spectrometry.Journal of the American Society for Mass Spectrometry · 2014Article
- Size, weight and position: ion mobility spectrometry and imaging MS combined.Analytical and bioanalytical chemistry · 2011Review
- Ultrahigh-resolution differential ion mobility spectrometry using extended separation times.Analytical chemistry · 2011Article
- Separation of peptide isomers with variant modified sites by high-resolution differential ion mobility spectrometry.Analytical chemistry · 2010Article
- High-resolution differential ion mobility separations using helium-rich gases.Analytical chemistry · 2010Article
- Chemical effects in the separation process of a differential mobility/mass spectrometer system.Analytical chemistry · 2010Article
- Differential ion mobility separations of peptides with resolving power exceeding 50.Analytical chemistry · 2010Article
- Ultrafast differential ion mobility spectrometry at extreme electric fields coupled to mass spectrometry.Analytical chemistry · 2009Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Differential mobility spectrometry or field asymmetric waveform ion mobility spectrometry (FAIMS) is gaining broad acceptance for analyses of gas-phase ions, especially in conjunction with largely orthogonal separation methods such as mass spectrometry (MS) and/or conventional (drift tube) ion mobility spectrometry. In FAIMS, ions are filtered while passing through a gap between two electrodes that may have planar or curved (in particular, cylindrical) geometry. Despite substantial inherent advantages of the planar configuration and its near-universal adoption in current stand-alone FAIMS devices, commercial FAIMS/MS systems have employed curved FAIMS geometries that can be more effectively interfaced to MS. Here we report a new planar (p-) FAIMS design with slit-shaped entrance and exit apertures that substantially increase ion transmission in and out of the analyzer. The entrance slit interface effectively couples p-FAIMS to multi-emitter electrospray ionization (ESI) sources, improving greatly the ion current introduced to the device and allowing liquid flow rates up to approximately 50 microL/min. The exit slit interface increases the transmission of ribbon-shaped ion beams output by the p-FAIMS to downstream stages such as a MS. Overall, the ion signal in ESI/FAIMS/MS analyses increases by over an order of magnitude without affecting FAIMS resolution.