Evidence map›Paper›PMID 19588337›Full record

SynthesisThe Cochrane database of systematic reviews2009

High frequency oscillatory ventilation versus conventional ventilation for infants with severe pulmonary dysfunction born at or near term.

David J Henderson-Smart, Antonio G De Paoli, Reese H Clark, Tushar Bhuta

Open access · bronzeAbstract readComparative StudySystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 2 pooled it
6.2field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 2 syntheses or guidelines pooled it, 88 citations in OpenAlex.

  1. Infant position in neonates receiving mechanical ventilation.The Cochrane database of systematic reviews · 2016
    Pooled it
  2. Pooled it
  3. Article
  4. Review
  5. Article
  6. Toward a Long-Term Artificial Lung.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2020
    Review
  7. Article
  8. High-frequency oscillatory ventilation: A narrative review.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2019
    Review
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. The design of future pediatric mechanical ventilation trials for acute lung injury.American journal of respiratory and critical care medicine · 2010
    Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

David J Henderson-SmartNSW Centre for Perinatal Health Services Research, Queen Elizabeth II Research Institute, Building DO2, University of Sydney, Sydney, NSW, Australia, 2006.
Antonio G De Paoli
Reese H Clark
Tushar Bhuta
Royal Hobart Hospital · AURoyal North Shore Hospital · AUUniversity of Sydney · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPulmonary disease is a major cause of mortality and morbidity in term and near term infants. Conventional ventilation (CV) has been used for many years but may lead to lung injury, require the subsequent use of more invasive treatment such as extracorporeal membrane oxygenation (ECMO), or result in death. There are some observational studies indicating that high frequency oscillatory ventilation (HFOV) may be more effective in these infants as compared to CV.

objectivesTo determine the effect of HFOV as compared with CV on mortality and morbidity in infants born at 35 weeks gestational age or more with severe respiratory failure requiring mechanical ventilation. SEARCH STRATEGY: Standard search methods of the Cochrane Neonatal Review group were used. These included searches in January 2009 of The Cochrane Library, MEDLINE, EMBASE, previous reviews including cross references, abstracts, conferences and symposia proceedings, expert informants, and journal hand searching by the Cochrane Collaboration. SELECTION CRITERIA: Randomized or quasi-randomized trials comparing HFOV and CV in term or near term infants with intractable respiratory failure were included in this review. DATA COLLECTION AND ANALYSIS: The standard methods of the Cochrane Neonatal Review Group were used. The investigators separately extracted, assessed and coded all data for each study. Any disagreement was resolved by discussion. Data were synthesized using risk ratio [RR with (95% confidence intervals, CI)] and mean difference (with standard deviation, SD). MAIN

resultsTwo trials met the inclusion criteria. One trial involving the "elective" use of HFOV randomized 118 infants at the start of CV. The other trial of "rescue" HFOV randomized 81 infants with later respiratory failure on CV. Neither trial showed evidence of a reduction in mortality at 28 days or in failed therapy on the assigned mode of ventilation requiring cross-over to the other mode. Neither study reported significant differences in the risk of pulmonary air leak, chronic lung disease (28 days or more in oxygen) or intracranial injury. In the study of elective HFOV, there was no difference noted in days on a ventilator or days in hospital. In the one rescue study, there was no difference in the risk of needing extracorporeal membrane oxygenation. AUTHORS'

conclusionsThere are no data from randomized controlled trials supporting the use of rescue HFOV in term or near term infants with severe pulmonary dysfunction. The area is complicated by diverse pathology in such infants and by the occurrence of other interventions (surfactant, inhaled nitric oxide, inotropes). Randomized controlled trials are needed to establish the role of elective or rescue HFOV in near term and term infants with pulmonary dysfunction before widespread use of this mode of ventilation in such infants.

Indexed as

High-Frequency VentilationHumansInfant, NewbornLung DiseasesRandomized Controlled Trials as TopicRespiration, ArtificialSalvage TherapyTerm BirthTreatment Outcome

Identifiers

PMID19588337
PMCPMC7004244
OpenAlexW1484146385

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.