ArticleBiomedical microdevices2009
Microfluidic compartmentalized co-culture platform for CNS axon myelination research.
Article in Biomedical microdevices, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 81 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
81 citing papers in PubMed.
- Microfluidic co-culture system for synaptically segregated neural networks to explore astrocyte-driven neural pathology.Microsystems & nanoengineering · 2026Article
- Article
- Nervous System-on-Chip: Innovative Microfluidic Platform to Compartmentalize hiPSC-Derived Neural Networks.Micromachines · 2026Article
- Advancing In Vitro Microfluidic Models for Pressure-Induced Retinal Ganglion Cell Degeneration: Current Insights and Future Directions from a Biomechanical Perspective.Micromachines · 2025Article
- Modeling neuroinflammatory interactions between microglia and astrocytes in a human iPSC-based coculture platform.Cell communication and signaling : CCS · 2025Article
- Animal models in neuroscience with alternative approaches: Evolutionary, biomedical, and ethical perspectives.Animal models and experimental medicine · 2024Review
- Prostaglandin E2 depolarises sensory axons in vitro in an ANO1 and Nav1.8 dependent manner.Scientific reports · 2024Article
- Review
- Microfluidic compartmentalization of rat vagal afferent neurons to model gut-brain axis.Bioelectronic medicine · 2024Article
- Modeling Gut Neuro-Epithelial Connections in a Novel Micro uidic Device.Research square · 2023Article
- Microfluidic Systems for Neural Cell Studies.Bioengineering (Basel, Switzerland) · 2023Review
- Modeling gut neuro-epithelial connections in a novel microfluidic device.Microsystems & nanoengineering · 2023Article
- Brain organoid-on-a-chip: A next-generation human brain avatar for recapitulating human brain physiology and pathology.Biomicrofluidics · 2022Article
- Role of Polymers in Microfluidic Devices.Polymers · 2022Review
- Microfluidics for Neuronal Cell and Circuit Engineering.Chemical reviews · 2022Review
- Advances in construction and modeling of functional neural circuits in vitro.Neurochemical research · 2022Article
- Promising Strategies for the Development of Advanced In Vitro Models with High Predictive Power in Ischaemic Stroke Research.International journal of molecular sciences · 2022Review
- In Vitro Methodologies to Study the Role of Advanced Glycation End Products (AGEs) in Neurodegeneration.Nutrients · 2022Review
- Modeling Neurodegenerative Diseases UsingFrontiers in bioengineering and biotechnology · 2022Review
- Novel, Emerging Chip Models of the Blood-Brain Barrier and Future Directions.Methods in molecular biology (Clifton, N.J.) · 2022Article
21 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
This paper presents a circular microfluidic compartmentalized co-culture platform that can be used for central nervous system (CNS) axon myelination research. The microfluidic platform is composed of a soma compartment and an axon/glia compartment connected through arrays of axon-guiding microchannels. Myelin-producing glia, oligodendrocytes (OLs), placed in the axon/glia compartment, interact with only axons but not with neuronal somata confined to the soma compartment, reminiscent to in vivo situation where many axon fibres are myelinated by OLs at distance away from neuronal cell bodies. Primary forebrain neurons from embryonic day 16-18 rats were cultured inside the soma compartment for two weeks to allow them to mature and form extensive axon networks. OL progenitors, isolated from postnatal day 1-2 rat brains, were then added to the axon/glia compartment and co-cultured with neurons for an additional two weeks. The microdevice showed fluidic isolation between the two compartments and successfully isolated neuronal cell bodies and dendrites from axons growing through the arrays of axon-guiding microchannels into the axon/glia compartment. The circular co-culture device developed here showed excellent cell loading characteristics where significant numbers of cells were positioned near the axon-guiding microchannels. This significantly increased the probability of axons crossing these microchannels as demonstrated by the more than 51 % of the area of the axon/glia compartment covered with axons two weeks after cell seeding. OL progenitors co-cultured with axons inside the axon/glia compartment successfully differentiated into mature OLs. These results indicate that this device can be used as an excellent in vitro co-culture platform for studying localized axon-glia interaction and signalling.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.