Evidence map›Paper›PMID 19548682›Full record

ArticleAnalytical chemistry2009

Microsphere-based rolling circle amplification microarray for the detection of DNA and proteins in a single assay.

Tania Konry, Ryan B Hayman, David R Walt

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
3.8field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 82 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Review
  14. Review
  15. Article
  16. Article
  17. Article
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Tania KonryDepartment of Chemistry, Tufts University, 62 Talbot Avenue, Medford, Massachusetts 02155, USA.
Ryan B Hayman
David R Walt
Tufts University · US

Funding

Microsensor Arrays for Saliva DiagnosticsU01DE017788 · NIDCR · TUFTS UNIVERSITY MEDFORD · PI WALT, DAVID R. · 2006 to 2010
$8.2M
Microsensor Arrays for Saliva DiagnosticsU01DE014950 · NIDCR · TUFTS UNIVERSITY MEDFORD · PI WALT, DAVID R. · 2002 to 2005
$3.8M
NIDCR NIH HHS U01 DE014950NIDCR NIH HHS U01 DE017788NIDCR NIH HHS U01-DE14950
6 · The paper itself

Abstract

We describe a high-density microarray for simultaneous detection of proteins and DNA in a single test. In this system, Rolling Circle Amplification (RCA) was used as a signal amplification method for both protein and nucleic acid detection. The microsphere sensors were tested with synthetic DNA and purified recombinant protein analytes. The target DNA sequence was designed from a highly conserved gene that encodes the outer membrane protein P6 (OMP-P6) of both typeable and nontypeable strains of Haemophilus influenzae. The proinflammatory mediators IL-6 and IL-8 were selected as target proteins. Capture antibodies were first immobilized on fluorescently encoded microspheres. The microspheres were then loaded into the etched microwells of an imaging optical fiber bundle. A sandwich assay was performed for target proteins IL-6 and IL-8 using biotin-labeled secondary antibodies. Biotinylated capture DNA probes were then attached to the detection antibodies via an avidin bridge. A padlock probe, complementary to the target sequence, was subsequently hybridized to the capture probe. In the presence of the target sequence, the padlock probe was ligated, and this circular sequence was used for RCA. Following RCA, multiple fluorescently labeled signal probes were hybridized to each amplified sequence, and the microarray was imaged using an epi-fluorescence microscope. With this assay, detection limits down to 10 fM and 1 pM were achieved for proteins and target DNA, respectively. In addition to this new approach for detecting both protein and DNA in a single test using RCA, the limit of detection for IL-8 and IL-6 was improved by 3 orders of magnitude compared to similar microsphere-based assays.

Indexed as

MicrospheresBiomarkersDNAHumansNucleic Acid Amplification TechniquesOligonucleotide Array Sequence AnalysisProtein Array AnalysisProteinsBiomarkersDNAProteins

Identifiers

PMID19548682
PMCPMC2730947
OpenAlexW1972790909

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.