ArticleIEEE transactions on bio-medical engineering2009
Real-time intravascular shear stress in the rabbit abdominal aorta.
Article in IEEE transactions on bio-medical engineering, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 25 citations in OpenAlex.
- Effects of Mechanical Stress on Endothelial Cells In Situ and In Vitro.International journal of molecular sciences · 2023Review
- Experimental Setting for Applying Mechanical Stimuli to Study the Endothelial Response of Ex Vivo Vessels under Realistic Pathophysiological Environments.Life (Basel, Switzerland) · 2021Article
- Assessment of a biofluid mechanics-based model for calculating portal pressure in canines.BMC veterinary research · 2020Article
- Determining Haemodynamic Wall Shear Stress in the Rabbit Aorta In Vivo Using Contrast-Enhanced Ultrasound Image Velocimetry.Annals of biomedical engineering · 2020Article
- Establishment and assessment of the hepatic venous pressure gradient using biofluid mechanics (HVPGBMJ open · 2019Article
- Hemodynamic numerical simulations of the disturbance due to intracoronary flow measurements by a Doppler guide wire.Biomedical engineering online · 2016Article
- Blood flow modulation of vascular dynamics.Current opinion in lipidology · 2015Review
- Flexible and waterproof micro-sensors to uncover zebrafish circadian rhythms: The next generation of cardiac monitoring for drug screening.Biosensors & bioelectronics · 2015Article
- Stretchable electrochemical impedance sensors for intravascular detection of lipid-rich lesions in New Zealand White rabbits.Biosensors & bioelectronics · 2014Article
- Atrial fibrillation pacing decreases intravascular shear stress in a New Zealand white rabbit model: implications in endothelial function.Biomechanics and modeling in mechanobiology · 2013Article
- MEMS thermal sensors to detect changes in heat transfer in the pre-atherosclerotic regions of fat-fed New Zealand white rabbits.Annals of biomedical engineering · 2011Article
- Electrochemical impedance spectroscopy to assess vascular oxidative stress.Annals of biomedical engineering · 2011Article
- Real-time assessment of flow reversal in an eccentric arterial stenotic model.Journal of biomechanics · 2010Article
- Optimization of intravascular shear stress assessment in vivo.Journal of biomechanics · 2009Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
Fluid shear stress is intimately linked with the biological activities of vascular cells. A flexible microelectromechanical system (MEMS) sensor was developed to assess spatial- and temporal-varying components of intravascular shear stress (ISS) in the abdominal aorta of adult New Zealand white (NZW) rabbits. Real-time ISS (ISS (real-time)) was analyzed in comparison with computational fluid dynamics (CFD) simulations for wall shear stress (WSS). Three-dimensional abdominal arterial geometry and mesh were created using the GAMBIT software. Simulation of arterial flow profiles was established by FLUENT. The Navier-Stokes equations were solved for non-Newtonian blood flow. The coaxial-wire-based MEMS sensor was deployed into the abdominal arteries of rabbits via a femoral artery cutdown. Based on the CFD analysis, the entrance length of the sensor on the coaxial wire (0.4 mm in diameter) was less than 10 mm. Three-dimensional fluoroscope and contrast dye allowed for visualization of the positions of the sensor and ratios of vessel to coaxial wire diameters. Doppler ultrasound provided the velocity profiles for the CFD boundary conditions. If the coaxial wire were positioned at the center of vessel, the CFD analysis revealed a mean ISS value of 31.1 with a systolic peak at 102.8 dyn x cm(-2). The mean WSS was computed to be 10.1 dyn x cm(-2) with a systolic peak at 33.2 dyn x cm(-2), and the introduction of coaxial wire increased the mean WSS by 5.4 dyn x cm(-2) and systolic peak by 18.0 dyn x cm(-2). Experimentally, the mean ISS was 11.9 dyn x cm(-2) with a systolic peak at 47.0 dyn x cm(-2). The waveform of experimental ISS was similar to that of CFD solution with a 30.2% difference in mean and 8.9% in peak systolic shear stress. Despite the difference between CD and experimental results, the flexible coaxial-wire-based MEMS sensors provided a possibility to assess real-time ISS in the abdominal aorta of NZW rabbits.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.