Evidence map›Paper›PMID 19527952›Full record

ArticleIEEE transactions on bio-medical engineering2009

Real-time intravascular shear stress in the rabbit abdominal aorta.

Lisong Ai, Hongyu Yu, Wangde Dai, Sharon L Hale, Robert A Kloner, Tzung K Hsiai

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
3.8field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 25 citations in OpenAlex.

  1. Effects of Mechanical Stress on Endothelial Cells In Situ and In Vitro.International journal of molecular sciences · 2023
    Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Blood flow modulation of vascular dynamics.Current opinion in lipidology · 2015
    Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Lisong AiDepartment of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089-1111, USA.
Hongyu Yu
Wangde Dai
Sharon L Hale
Robert A Kloner
Tzung K Hsiai
University of Southern California · USGood Samaritan Hospital · US

Funding

Linking Spatial Variations Shear Stress-Oxidative StressR01HL083015 · NHLBI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI HSIAI, TZUNG K · 2006 to 2015
$3.9M
Electronica Impedance to Access Metabolically Active PlaqueR01HL118650 · NHLBI · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI HSIAI, TZUNG K · 2014 to 2022
$3.3M
Microsensors to Study Endothelial Cell DynamicsK08HL068689 · NHLBI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI HSIAI, TZUNG K · 2003 to 2007
$514k
NHLBI NIH HHS HL068689NHLBI NIH HHS HL83015NHLBI NIH HHS K08 HL068689NHLBI NIH HHS R01 HL083015NHLBI NIH HHS R01 HL118650
6 · The paper itself

Abstract

Fluid shear stress is intimately linked with the biological activities of vascular cells. A flexible microelectromechanical system (MEMS) sensor was developed to assess spatial- and temporal-varying components of intravascular shear stress (ISS) in the abdominal aorta of adult New Zealand white (NZW) rabbits. Real-time ISS (ISS (real-time)) was analyzed in comparison with computational fluid dynamics (CFD) simulations for wall shear stress (WSS). Three-dimensional abdominal arterial geometry and mesh were created using the GAMBIT software. Simulation of arterial flow profiles was established by FLUENT. The Navier-Stokes equations were solved for non-Newtonian blood flow. The coaxial-wire-based MEMS sensor was deployed into the abdominal arteries of rabbits via a femoral artery cutdown. Based on the CFD analysis, the entrance length of the sensor on the coaxial wire (0.4 mm in diameter) was less than 10 mm. Three-dimensional fluoroscope and contrast dye allowed for visualization of the positions of the sensor and ratios of vessel to coaxial wire diameters. Doppler ultrasound provided the velocity profiles for the CFD boundary conditions. If the coaxial wire were positioned at the center of vessel, the CFD analysis revealed a mean ISS value of 31.1 with a systolic peak at 102.8 dyn x cm(-2). The mean WSS was computed to be 10.1 dyn x cm(-2) with a systolic peak at 33.2 dyn x cm(-2), and the introduction of coaxial wire increased the mean WSS by 5.4 dyn x cm(-2) and systolic peak by 18.0 dyn x cm(-2). Experimentally, the mean ISS was 11.9 dyn x cm(-2) with a systolic peak at 47.0 dyn x cm(-2). The waveform of experimental ISS was similar to that of CFD solution with a 30.2% difference in mean and 8.9% in peak systolic shear stress. Despite the difference between CD and experimental results, the flexible coaxial-wire-based MEMS sensors provided a possibility to assess real-time ISS in the abdominal aorta of NZW rabbits.

Indexed as

Pulsatile FlowStress, MechanicalAnimalsAorta, AbdominalBlood Flow VelocityComputer SimulationEquipment DesignHemorheologyMaleMicro-Electrical-Mechanical SystemsProstheses and ImplantsRabbitsShear StrengthSoftwareUltrasonography, Doppler

Identifiers

PMID19527952
PMCPMC3320657
OpenAlexW2132718809

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.