ArticleMagnetic resonance in medicine2009
Breathhold multiecho fast spin-echo pulse sequence for accurate R2 measurement in the heart and liver.
Article in Magnetic resonance in medicine, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
30 citing papers in PubMed.
- Fast and High-Resolution luminal water imaging for prostate cancer diagnosis.Magnetic resonance in medicine · 2025Article
- Cardiac MR Fingerprinting: Overview, Technical Developments, and Applications.Journal of magnetic resonance imaging : JMRI · 2024Review
- Validation of conductivity tensor imaging against diffusion tensor magnetic resonance electrical impedance tomography.Scientific reports · 2024Article
- Developing a medical device-grade TJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023Article
- Pseudo-T2 mapping for normalization of T2-weighted prostate MRI.Magma (New York, N.Y.) · 2022Article
- T2 mapping in myocardial disease: a comprehensive review.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2022Review
- Fast TMagnetic resonance in medicine · 2020Article
- Black blood myocardial TMagnetic resonance in medicine · 2019Article
- Inter-method reproducibility of biexponential RMagnetic resonance in medicine · 2018Article
- A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2018Article
- Advanced imaging techniques in pediatric body MRI.Pediatric radiology · 2017Review
- Accelerated and motion-robust in vivo T2 mapping from radially undersampled data using bloch-simulation-based iterative reconstruction.Magnetic resonance in medicine · 2016Article
- Wideband arrhythmia-Insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by an implantable-cardioverter-defibrillator.Magnetic resonance in medicine · 2015Article
- T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2015Article
- Rapid and accurate T2 mapping from multi-spin-echo data using Bloch-simulation-based reconstruction.Magnetic resonance in medicine · 2015Article
- Article
- Mapping myocarditis: still searching for the north star.JACC. Cardiovascular imaging · 2014Article
- Cardiac magnetic resonance imaging for the investigation of cardiovascular disorders. Part 2: emerging applications.Texas Heart Institute journal · 2014Review
- MR characterization of hepatic storage iron in transfusional iron overload.Journal of magnetic resonance imaging : JMRI · 2014Article
- Accelerated fast spin-echo magnetic resonance imaging of the heart using a self-calibrated split-echo approach.PloS one · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Measurement of proton transverse relaxation rates (R(2)) is a generally useful means for quantitative characterization of pathological changes in tissue with a variety of clinical applications. The most widely used R(2) measurement method is the Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence but its relatively long scan time requires respiratory gating for chest or body MRI, rendering this approach impractical for comprehensive assessment within a clinically-acceptable examination time. The purpose of our study was to develop a breathhold multiecho fast spin-echo (FSE) sequence for accurate measurement of R(2) in the liver and heart. Phantom experiments and studies of subjects in vivo were performed to compare the FSE data with the corresponding even-echo CPMG data. For pooled data, the R(2) measurements were strongly correlated (Pearson correlation coefficient = 0.99) and in excellent agreement (mean difference [CPMG - FSE] = 0.10 s(-1); 95% limits of agreement were 1.98 and -1.78 s(-1)) between the two pulse sequences.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.