Evidence map›Paper›PMID 19473537›Full record

ArticleBMC bioinformatics2009

Hydra: software for tailored processing of H/D exchange data from MS or tandem MS analyses.

Gordon W Slysz, Charles A H Baker, Benjamin M Bozsa, Anthony Dang, Andrew J Percy, Melissa Bennett, David C Schriemer

Abstract read
In one paragraph

Article in BMC bioinformatics, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 40 papers.

0numbers the graph read from it
0cells of the map it votes in
40citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

40 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Hydrogen Exchange Mass Spectrometry.Methods in enzymology · 2016
    Article
  14. Review
  15. Article
  16. Mass spec studio for integrative structural biology.Structure (London, England : 1993) · 2014
    Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Gordon W SlyszDepartment of Biochemistry and Molecular Biology, University of Calgary, Calgary, Alberta, T2N 4N1, Canada. gslysz@ucalgary.ca
Charles A H Baker
Benjamin M Bozsa
Anthony Dang
Andrew J Percy
Melissa Bennett
David C Schriemer

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHydrogen/deuterium exchange mass spectrometry (H/DX-MS) experiments implemented to characterize protein interaction and protein folding generate large quantities of data. Organizing, processing and visualizing data requires an automated solution, particularly when accommodating new tandem mass spectrometry modes for H/DX measurement. We sought to develop software that offers flexibility in defining workflows so as to support exploratory treatments of H/DX-MS data, with a particular focus on the analysis of very large protein systems and the mining of tandem mass spectrometry data.

resultsWe present a software package ("Hydra") that supports both traditional and exploratory treatments of H/DX-MS data. Hydra's software architecture tolerates flexible data analysis procedures by allowing the addition of new algorithms without significant change to the underlying code base. Convenient user interfaces ease the organization of raw data files and input of peptide data. After executing a user-defined workflow, extracted deuterium incorporation values can be visualized in tabular and graphical formats. Hydra also automates the extraction and visualization of deuterium distribution values. Manual validation and assessment of results is aided by an interface that aligns extracted ion chromatograms and mass spectra, while providing a means of rapidly reprocessing the data following manual adjustment. A unique feature of Hydra is the automated processing of tandem mass spectrometry data, demonstrated on a large test data set in which 40,000 deuterium incorporation values were extracted from replicate analysis of approximately 1000 fragment ions in one hour using a typical PC.

conclusionThe customizable workflows and user-friendly interfaces of Hydra removes a significant bottleneck in processing and visualizing H/DX-MS data and helps the researcher spend more time executing new experiments and interpreting results. This increased efficiency will encourage the analysis of larger protein systems. The ability to accommodate the tandem MS dimension supports alternative data collection and analysis strategies, as well as higher resolution localization of deuteration where permitted by the fragmentation mechanism.

Indexed as

Deuterium Exchange MeasurementMass SpectrometrySoftwareTandem Mass SpectrometryAlgorithmsComputer GraphicsDatabases, ProteinModels, StatisticalPeptide FragmentsPeptidesProtein FoldingProtein Interaction Domains and MotifsProteinsReproducibility of ResultsUser-Computer InterfacePeptide FragmentsPeptidesProteins

Identifiers

PMID19473537
PMCPMC2696453

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.