Evidence map›Paper›PMID 19457490›Full record

ArticleJournal of biomechanics2009

Optimization of intravascular shear stress assessment in vivo.

Lisong Ai, Hongyu Yu, Wakako Takabe, Anna Paraboschi, Fei Yu, E S Kim, Rongsong Li, Tzung K Hsiai

Abstract read
In one paragraph

Article in Journal of biomechanics, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.9field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 20 citations in OpenAlex.

  1. Recent Progress in Blood Flow Sensing.Sensors and actuators. A, Physical · 2025
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Lisong AiDepartment of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089-1111, United States.
Hongyu YuDepartment of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089-1111, United States.
Wakako TakabeDepartment of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089-1111, United States.
Anna ParaboschiDepartment of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089-1111, United States.
Fei YuDepartment of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089-1111, United States.
E S KimDepartment of Electrical Engineering and Electrophysics, University of Southern California, Los Angeles, CA 90089-1111, United States.
Rongsong LiDepartment of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089-1111, United States.
Tzung K HsiaiDepartment of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089-1111, United States. Electronic address: hsiai@usc.edu.
University of Southern California · US

Funding

Linking Spatial Variations Shear Stress-Oxidative StressR01HL083015 · NHLBI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI HSIAI, TZUNG K · 2006 to 2015
$3.9M
Electronica Impedance to Access Metabolically Active PlaqueR01HL118650 · NHLBI · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI HSIAI, TZUNG K · 2014 to 2022
$3.3M
Microsensors to Study Endothelial Cell DynamicsK08HL068689 · NHLBI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI HSIAI, TZUNG K · 2003 to 2007
$514k
NHLBI NIH HHS K08 HL068689NHLBI NIH HHS R01 HL083015NHLBI NIH HHS R01 HL118650
6 · The paper itself

Abstract

The advent of microelectromechanical systems (MEMS) sensors has enabled real-time wall shear stress (WSS) measurements with high spatial and temporal resolution in a 3-D bifurcation model. To optimize intravascular shear stress assessment, we evaluated the feasibility of catheter/coaxial wire-based MEMS sensors in the abdominal aorta of the New Zealand white (NZW) rabbits. Theoretical and computational fluid dynamics (CFD) analyses were performed. Fluoroscope and angiogram provided the geometry of aorta, and the Doppler ultrasound system provided the pulsatile flow velocity for the boundary conditions. The physical parameters governing the shear stress assessment in NZW rabbits included (1) the position and distance from which the MEMS sensors were mounted to the terminal end of coaxial wire or the entrance length, (L(e)), (2) diameter ratios of aorta to the coaxial wire (D(aorta) /D(coaxial wire)=1.5-9.5), and (3) the range of Reynolds numbers (116-1550). At an aortic diameter of 2.4mm and a maximum Reynolds number of 212 (a mean Reynolds number of 64.2), the time-averaged shear stress (tau(ave)) was computed to be 10.06 dyn cm(-2) with a systolic peak at 33.18 dyn cm(-2). In the presence of a coaxial wire (D(aorta)/D(coaxial wire)=6 and L(e)=1.18 cm), the tau(ave) value increased to 15.54 dyn cm(-2) with a systolic peak at 51.25 dyn cm(-2). Real-time intravascular shear stress assessment by the MEMS sensor revealed an tau(ave) value of 11.92 dyn cm(-2) with a systolic peak at 47.04 dyn cm(-2). The difference between CFD and experimental tau(ave) was 18.5%. These findings provided important insights into packaging the MEMS sensors to optimize in vivo shear stress assessment.

Indexed as

HemorheologyModels, CardiovascularAnimalsAorta, AbdominalBiomechanical PhenomenaBiomedical EngineeringImaging, Three-DimensionalRabbitsRadiographyStress, MechanicalUltrasonography

Identifiers

PMID19457490
PMCPMC2777988
OpenAlexW2008371699

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.