ArticleJournal of biomechanics2009
Optimization of intravascular shear stress assessment in vivo.
Article in Journal of biomechanics, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 20 citations in OpenAlex.
- Recent Progress in Blood Flow Sensing.Sensors and actuators. A, Physical · 2025Article
- Flexible and waterproof micro-sensors to uncover zebrafish circadian rhythms: The next generation of cardiac monitoring for drug screening.Biosensors & bioelectronics · 2015Article
- Atrial fibrillation pacing decreases intravascular shear stress in a New Zealand white rabbit model: implications in endothelial function.Biomechanics and modeling in mechanobiology · 2013Article
- Elevated electrochemical impedance in the endoluminal regions with high shear stress: implication for assessing lipid-rich atherosclerotic lesions.Biosensors & bioelectronics · 2013Article
- Prospective nonrandomized comparison of quality of life and recurrence between high ligation and stripping and radiofrequency ablation for varicose veins.Journal of the Korean Surgical Society · 2013Article
- MEMS thermal sensors to detect changes in heat transfer in the pre-atherosclerotic regions of fat-fed New Zealand white rabbits.Annals of biomedical engineering · 2011Article
- Real-time assessment of flow reversal in an eccentric arterial stenotic model.Journal of biomechanics · 2010Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
The advent of microelectromechanical systems (MEMS) sensors has enabled real-time wall shear stress (WSS) measurements with high spatial and temporal resolution in a 3-D bifurcation model. To optimize intravascular shear stress assessment, we evaluated the feasibility of catheter/coaxial wire-based MEMS sensors in the abdominal aorta of the New Zealand white (NZW) rabbits. Theoretical and computational fluid dynamics (CFD) analyses were performed. Fluoroscope and angiogram provided the geometry of aorta, and the Doppler ultrasound system provided the pulsatile flow velocity for the boundary conditions. The physical parameters governing the shear stress assessment in NZW rabbits included (1) the position and distance from which the MEMS sensors were mounted to the terminal end of coaxial wire or the entrance length, (L(e)), (2) diameter ratios of aorta to the coaxial wire (D(aorta) /D(coaxial wire)=1.5-9.5), and (3) the range of Reynolds numbers (116-1550). At an aortic diameter of 2.4mm and a maximum Reynolds number of 212 (a mean Reynolds number of 64.2), the time-averaged shear stress (tau(ave)) was computed to be 10.06 dyn cm(-2) with a systolic peak at 33.18 dyn cm(-2). In the presence of a coaxial wire (D(aorta)/D(coaxial wire)=6 and L(e)=1.18 cm), the tau(ave) value increased to 15.54 dyn cm(-2) with a systolic peak at 51.25 dyn cm(-2). Real-time intravascular shear stress assessment by the MEMS sensor revealed an tau(ave) value of 11.92 dyn cm(-2) with a systolic peak at 47.04 dyn cm(-2). The difference between CFD and experimental tau(ave) was 18.5%. These findings provided important insights into packaging the MEMS sensors to optimize in vivo shear stress assessment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.