Evidence map›Paper›PMID 19454009›Full record

ArticleCritical care (London, England)2009

Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring.

Sophie Marqué, Alain Cariou, Jean-Daniel Chiche, Pierre Squara

2 registry-linked trialsAbstract readComparative StudyValidation Study
In one paragraph

Article in Critical care (London, England), 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 45 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
45citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03394768 terminatednot on this mapstarted 2018, after this paper: background citation

An Observational Study Comparing NICOM-Cheetah Versus Flotrac-Vigileo for Cardiac Output Monitoring in the Surgical Intensive Care Unit.

Typeobservational_patient_registrySponsorChangi General HospitalRan2018 to 2021Enrolled26ConditionsCardiac Output, LowArmsNo additional intervention
NCT03893513 completednot on this mapstarted 2019, after this paper: background citation

Comparison of Transthoracic Electrical Bioimpedance and Pulse Contour Analysis in Renal Transplantation Patients: Analysis of Intraoperative Cardiac Output, Systemic Vascular Resistant and Stroke Volume Variation

TypeobservationalSponsorDita AditianingsihRan2019 to 2019Enrolled50ConditionsHemodynamic MonitoringArmsTransthoracic Electrical Bioimpedance, Pulse Contour Analysis
3 · Its place in the literature

Who cites it

45 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Trial
  6. Trial
  7. Review
  8. Article
  9. Non-invasive continuous cardiac output monitoring in infants with hypoxic ischaemic encephalopathy.Journal of perinatology : official journal of the California Perinatal Association · 2022
    Observational
  10. Article
  11. Article
  12. Observational
  13. Article
  14. Review
  15. Article
  16. Emergency department non-invasive cardiac output study (EDNICO): an accuracy study.Scandinavian journal of trauma, resuscitation and emergency medicine · 2020
    Observational
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Sophie MarquéMedical Intensive Care Unit, Cochin Hospital, 75679 Paris Cedex 14, France. sophie.marque@cch.aphp.fr
Alain Cariou
Jean-Daniel Chiche
Pierre Squara

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThis study was designed to compare the clinical acceptability of two cardiac output (CO) monitoring systems: a pulse wave contour-based system (FloTrac-Vigileo) and a bioreactance-based system (NICOM), using continuous thermodilution (PAC-CCO) as a reference method.

methodsConsecutive patients, requiring PAC-CCO monitoring following cardiac surgery, were also monitored by the two other devices. CO values obtained simultaneously by the three systems were recorded continuously on a minute-by-minute basis.

resultsContinuous recording was performed on 29 patients, providing 12,099 simultaneous measurements for each device (417 +/- 107 per patient). In stable conditions, correlations of NICOM and Vigileo with PAC-CCO were 0.77 and 0.69, respectively. The bias was -0.01 +/- 0.84 for NICOM and -0.01 +/- 0.81 for Vigileo (NS). NICOM relative error was less than 30% in 94% of the patients and less than 20% in 79% vs. 91% and 79% for the Vigileo, respectively (NS). The variability of measurements around the trend line (precision) was not different between the three methods: 8 +/- 3%, 8 +/- 4% and 8 +/- 3% for PAC-CCO, NICOM and Vigileo, respectively. CO changes were 7.2 minutes faster with Vigileo and 6.9 minutes faster with NICOM (P < 0.05 both systems vs. PAC-CCO, NS). Amplitude of changes was not significantly different than thermodilution. Finally, the sensitivity and specificity for predicting significant CO changes were 0.91 and 0.95 respectively for the NICOM and 0.86 and 0.92 respectively for the Vigileo.

conclusionThis study showed that the NICOM and Vigileo devices have similar monitoring capabilities in post-operative cardiac surgery patients.

Indexed as

Cardiac OutputCardiac Surgical ProceduresFemaleHeart Function TestsHumansMaleMiddle AgedMonitoring, PhysiologicPostoperative CareReproducibility of ResultsSensitivity and Specificity

Identifiers

PMID19454009
PMCPMC2717435

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.