ArticleFrontiers in neuroengineering2009
Carbon nanotube electrodes for effective interfacing with retinal tissue.
Article in Frontiers in neuroengineering, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed.
- Can bionic eyes restore vision? Breakthroughs, challenges, and future frontiers in ophthalmology - A comprehensive review.Journal of biological engineering · 2025Article
- Review
- A Review: Research Progress of Neural Probes for Brain Research and Brain-Computer Interface.Biosensors · 2022Review
- Potential therapeutic strategies for photoreceptor degeneration: the path to restore vision.Journal of translational medicine · 2022Review
- Vitamin C-reduced graphene oxide improves the performance and stability of multimodal neural microelectrodes.iScience · 2022Article
- Optoelectronic Neural Interfaces Based on Quantum Dots.ACS applied materials & interfaces · 2022Review
- Soft Devices for High-Resolution Neuro-Stimulation: The Interplay Between Low-Rigidity and Resolution.Frontiers in medical technology · 2021Review
- Connecting concrete technology and machine learning: proposal for application of ANNs and CNT/concrete composites in structural health monitoring.RSC advances · 2020Review
- The combination of brain-computer interfaces and artificial intelligence: applications and challenges.Annals of translational medicine · 2020Review
- The Roles of an Aluminum Underlayer in the Biocompatibility and Mechanical Integrity of Vertically Aligned Carbon Nanotubes for Interfacing with Retinal Neurons.Micromachines · 2020Article
- Carbon nanotube electrodes for retinal implants: A study of structural and functional integration over time.Biomaterials · 2017Article
- Visual Prosthesis: Interfacing Stimulating Electrodes with Retinal Neurons to Restore Vision.Frontiers in neuroscience · 2017Review
- Carbon Nanomaterials Interfacing with Neurons: An In vivo Perspective.Frontiers in neuroscience · 2016Review
- Semiconductor nanorod-carbon nanotube biomimetic films for wire-free photostimulation of blind retinas.Nano letters · 2014Article
- A review of organic and inorganic biomaterials for neural interfaces.Advanced materials (Deerfield Beach, Fla.) · 2014Review
- All-carbon-nanotube flexible multi-electrode array for neuronal recording and stimulation.Biomedical microdevices · 2014Article
- Organic electrode coatings for next-generation neural interfaces.Frontiers in neuroengineering · 2014Review
- Smaller, softer, lower-impedance electrodes for human neuroprosthesis: a pragmatic approach.Frontiers in neuroengineering · 2014Article
- Article
- Biomaterials-based electronics: polymers and interfaces for biology and medicine.Advanced healthcare materials · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We have investigated the use of carbon nanotube coated microelectrodes as an interface material for retinal recording and stimulation applications. Test devices were micro-fabricated and consisted of 60, 30 mum diameter electrodes at spacing of 200 mum. These electrodes were coated via chemical vapor deposition of carbon nanotubes, resulting in conducting, three dimensional surfaces with a high interfacial area. These attributes are important both for the quality of the cell-surface coupling as well as for electro-chemical interfacing efficiency. The entire chip was packaged to fit a commercial multielectrode recording and stimulation system. Electrical recordings of spontaneous spikes from whole-mount neonatal mouse retinas were consistently obtained minutes after retinas were placed over the electrodes, exhibiting typical bursting and propagating waves. Most importantly, the signals obtained with carbon nanotube electrodes have exceptionally high signal to noise ratio, reaching values as high as 75. Moreover, spikes are marked by a conspicuous gradual increase in amplitude recorded over a period of minutes to hours, suggesting improvement in cell-electrode coupling. This phenomenon is not observed in conventional commercial electrodes. Electrical stimulation using carbon nanotube electrodes was also achieved. We attribute the superior performances of the carbon nanotube electrodes to their three dimensional nature and the strong neuro-carbon nanotube affinity. The results presented here show the great potential of carbon nanotube electrodes for retinal interfacing applications. Specifically, our results demonstrate a route to achieve a reduction of the electrode down to few micrometers in order to achieve high efficacy local stimulation needed in retinal prosthetic devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.