Evidence map›Paper›PMID 19430595›Full record

ArticleFrontiers in neuroengineering2009

Carbon nanotube electrodes for effective interfacing with retinal tissue.

Asaf Shoval, Christopher Adams, Moshe David-Pur, Mark Shein, Yael Hanein, Evelyne Sernagor

Abstract read
In one paragraph

Article in Frontiers in neuroengineering, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Article
  6. Optoelectronic Neural Interfaces Based on Quantum Dots.ACS applied materials & interfaces · 2022
    Review
  7. Review
  8. Review
  9. Review
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. A review of organic and inorganic biomaterials for neural interfaces.Advanced materials (Deerfield Beach, Fla.) · 2014
    Review
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Asaf ShovalSchool of Electrical Engineering, Tel-Aviv University Tel-Aviv, Israel.
Christopher Adams
Moshe David-Pur
Mark Shein
Yael Hanein
Evelyne Sernagor

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We have investigated the use of carbon nanotube coated microelectrodes as an interface material for retinal recording and stimulation applications. Test devices were micro-fabricated and consisted of 60, 30 mum diameter electrodes at spacing of 200 mum. These electrodes were coated via chemical vapor deposition of carbon nanotubes, resulting in conducting, three dimensional surfaces with a high interfacial area. These attributes are important both for the quality of the cell-surface coupling as well as for electro-chemical interfacing efficiency. The entire chip was packaged to fit a commercial multielectrode recording and stimulation system. Electrical recordings of spontaneous spikes from whole-mount neonatal mouse retinas were consistently obtained minutes after retinas were placed over the electrodes, exhibiting typical bursting and propagating waves. Most importantly, the signals obtained with carbon nanotube electrodes have exceptionally high signal to noise ratio, reaching values as high as 75. Moreover, spikes are marked by a conspicuous gradual increase in amplitude recorded over a period of minutes to hours, suggesting improvement in cell-electrode coupling. This phenomenon is not observed in conventional commercial electrodes. Electrical stimulation using carbon nanotube electrodes was also achieved. We attribute the superior performances of the carbon nanotube electrodes to their three dimensional nature and the strong neuro-carbon nanotube affinity. The results presented here show the great potential of carbon nanotube electrodes for retinal interfacing applications. Specifically, our results demonstrate a route to achieve a reduction of the electrode down to few micrometers in order to achieve high efficacy local stimulation needed in retinal prosthetic devices.

Indexed as

biocompatibilitycarbon nanotubemultielectrode arrayneural implantretina

Identifiers

PMID19430595
PMCPMC2679158

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.