ArticlePhysics in medicine and biology2009
Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection.
Article in Physics in medicine and biology, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 35 citations in OpenAlex.
- Deep Image Prior-Incorporated Direct PET Parametric Image Reconstruction.IEEE transactions on medical imaging · 2026Article
- Article
- Cardiac PET/CT with Rb-82: optimization of image acquisition and reconstruction parameters.EJNMMI physics · 2017Article
- Exact confidence intervals for channelized Hotelling observer performance in image quality studies.IEEE transactions on medical imaging · 2015Article
- Importance of Defect Detectability in Positron Emission Tomography Imaging of Abdominal Lesions.Asia Oceania journal of nuclear medicine & biology · 2015Article
- Myocardial defect detection using PET-CT: phantom studies.PloS one · 2014Article
- Noise propagation in resolution modeled PET imaging and its impact on detectability.Physics in medicine and biology · 2013Article
- New Theoretical Results on Channelized Hotelling Observer Performance Estimation with Known Difference of Class Means.IEEE transactions on nuclear science · 2013Article
- Accuracy of low-dose rubidium-82 myocardial perfusion imaging for detection of coronary artery disease using 3D PET and normal database interpretation.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2012Article
- Generation and Evaluation of a Simultaneous Cardiac and Respiratory Gated Rb-82 PET Simulation.IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium · 2011Article
- Development of a model of the coronary arterial tree for the 4D XCAT phantom.Physics in medicine and biology · 2011Article
- Simultaneous measurement of noise and spatial resolution in PET phantom images.Physics in medicine and biology · 2010Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
The purpose of this study is to optimize the dynamic Rb-82 cardiac PET acquisition and reconstruction protocols for maximum myocardial perfusion defect detection using realistic simulation data and task-based evaluation. Time activity curves (TACs) of different organs under both rest and stress conditions were extracted from dynamic Rb-82 PET images of five normal patients. Combined SimSET-GATE Monte Carlo simulation was used to generate nearly noise-free cardiac PET data from a time series of 3D NCAT phantoms with organ activities modeling different pre-scan delay times (PDTs) and total acquisition times (TATs). Poisson noise was added to the nearly noise-free projections and the OS-EM algorithm was applied to generate noisy reconstructed images. The channelized Hotelling observer (CHO) with 32x32 spatial templates corresponding to four octave-wide frequency channels was used to evaluate the images. The area under the ROC curve (AUC) was calculated from the CHO rating data as an index for image quality in terms of myocardial perfusion defect detection. The 0.5 cycle cm(-1) Butterworth post-filtering on OS-EM (with 21 subsets) reconstructed images generates the highest AUC values while those from iteration numbers 1 to 4 do not show different AUC values. The optimized PDTs for both rest and stress conditions are found to be close to the cross points of the left ventricular chamber and myocardium TACs, which may promote an individualized PDT for patient data processing and image reconstruction. Shortening the TATs for <approximately 3 min from the clinically employed acquisition time does not affect the myocardial perfusion defect detection significantly for both rest and stress studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.