Calibration accuracy of hospital-based non-invasive blood pressure measuring devices.
Article in Journal of human hypertension, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 1 synthesis or guideline pooled it, 49 citations in OpenAlex.
- Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.Journal of hypertension · 2017Pooled it
- Clinical validation of a wearable ultrasound sensor of blood pressure.Nature biomedical engineering · 2025Article
- Article
- Accuracy of oscillometric-based blood pressure monitoring devices: impact of pulse volume, arrhythmia, and respiratory artifact.Journal of human hypertension · 2024Article
- The urgency to regulate validation of automated blood pressure measuring devices: a policy statement and call to action from the world hypertension league.Journal of human hypertension · 2023Review
- Article
- Low cost, non-invasive, and continuous vital signs monitoring device for pregnant women in low resource settings (Lvital device).HardwareX · 2022Article
- Results of a project to calibrate mercury sphygmomanometer blood pressure-measuring devices in Egypt.Journal of human hypertension · 2021Article
- A survey on personnel awareness of the factors affecting accurate blood pressure measurement in the medical centres of Jahrom County.Nursing open · 2020Article
- Wearable skin-like optoelectronic systems with suppression of motion artifacts for cuff-less continuous blood pressure monitor.National science review · 2020Article
- Accuracy of monitors used for blood pressure checks in English retail pharmacies: a cross-sectional observational study.The British journal of general practice : the journal of the Royal College of General Practitioners · 2016Observational
- Problems and Solutions in Implementing the World Hypertension League Recommendations for Automated Office Assessment of Blood Pressure.Journal of clinical hypertension (Greenwich, Conn.) · 2016Article
- Challenges in standardization of blood pressure measurement at the population level.BMC medical research methodology · 2015Article
- Policy statement of the world hypertension league on noninvasive blood pressure measurement devices and blood pressure measurement in the clinical or community setting.Journal of clinical hypertension (Greenwich, Conn.) · 2014Review
- Meaningful measurement: developing a measurement system to improve blood pressure control in patients with chronic kidney disease.Journal of the American Medical Informatics Association : JAMIA · 2013Article
- Diagnosis and management of preeclampsia in community settings in low and middle-income countries.Journal of family medicine and primary careReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Accurate blood pressure (BP) measurement is dependent on a trained observer using validated and properly maintained equipment. BP devices should be checked regularly to ensure that their calibration remains within the European Standard specification of +/-3 mm Hg. This study assessed the air leakage rates and calibration accuracy of BP devices in use at a large teaching hospital, using a calibrated electronic pressure gauge as reference. Air leakage rates were recorded over 1 min and static pressures were recorded at 250/200/150/100/50/0 mm Hg for computer download and analysis. A total of 127 devices were assessed (18 mercury, 62 aneroid and 47 automated). In total, 22 different models of devices were available, of which 11 were automated and only 4 had published evidence of a validation using a recognized protocol (British Hypertension Society, Association for the Advancement of Medical Instrumentation or International Protocol). Only 3% (n=4) of devices had an air leakage rate within 4 mm Hg per min and 25% (n=32) of devices failed to meet the European calibration standard of +/-3 mm Hg. Respective failure rates were 6% (1/18) for mercury, 31% (19/62) for aneroid and 26% (12/47) for automated devices. Inaccurate BP measurement of only 3 mm Hg can have detrimental effects in the patient. This study shows a quarter of devices currently in use at a large teaching hospital to have an unacceptable calibration error. Regular maintenance and calibration checks are vital in ensuring that BP is measured as accurately as possible.