Evidence map›Paper›PMID 19330503›Full record

ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2009

High-performance self-expanding stent graft: development and application to experimental aneurysms.

Shogo Nishi, Yasuhide Nakayama, Hatsue Ishibashi-Ueda, Yoshihiro Okamoto, Yusuke Kinoshita

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 15 citations in OpenAlex.

  1. Review
  2. Article
  3. Development of microporous self-expanding stent grafts for treating cerebral aneurysms: designing micropores to control intimal hyperplasia.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2011
    Article
  4. Journal of Artificial Organs 2009: the year in review.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2010
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Shogo NishiDepartment of Neurosurgery, Interventional Neurosurgery, and Spinal Surgery, Sapporo Higashi-Tokushukai Hospital, 14-3-1 Higashi, Higashi-ku, Sapporo, Japan. nishi@higashi-tokushukai.or.jp
Yasuhide Nakayama
Hatsue Ishibashi-Ueda
Yoshihiro Okamoto
Yusuke Kinoshita
Sapporo Higashi Tokushukai Hospital · JPBridgestone (Japan) · JPNational Cerebral and Cardiovascular Center · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Large or giant aneurysms in the craniocervical area with broad necks are of concern and are treated surgically, endovascularly, or in both ways. Surgically, their treatment is difficult, with relatively high risks. For their embolization, we have been developing a high-performance stent graft that has three characteristics: a thin and expandable segmented polyurethane (SPU) membrane, micropores formed by the excimer laser ablation technique, and a drug delivery system at the membrane. Stent grafts were fabricated using commercially available self-expanding stents. These stents were covered with a thin SPU membrane by the dip-coating method. Micropores were then formed by the excimer laser ablation technique and an argatroban coating was added. We tested the effectiveness of this new stent graft by treating experimental canine aneurysms. Experimental aneurysms were made in the bilateral carotid arteries of four female beagles by end-to-side anastomosis using an autologous venous pouch. One month after aneurysm formation, the experimental aneurysm in one of the carotid arteries was covered with our self-expanding stent graft and the aneurysm in the other artery was covered with a bare self-expanding stent. On angiograms 1 month after stenting, the aneurysms treated with our stent graft were completely occluded without significant parent artery stenosis, but the aneurysms treated with the original bare stent were still open. Our high-performance self-expanding stent graft was easily applied to the experimental aneurysms and accomplished complete occlusion of aneurysms in beagles. Further study should be performed for the goal of clinical use.

Indexed as

Drug-Eluting StentsProsthesis ImplantationAneurysmAngiographyAnimalsCarotid ArteriesCarotid Artery DiseasesDogsFemaleProsthesis Design

Identifiers

PMID19330503
OpenAlexW2055194064

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.