Evidence map›Paper›PMID 19256649›Full record

ArticleThe Review of scientific instruments2009

Thermally actuated tapping mode atomic force microscopy with polymer microcantilevers.

Bhaskar Mitra, Angelo Gaitas

Abstract read
In one paragraph

Article in The Review of scientific instruments, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Bhaskar MitraPicoCal Inc., Ann Arbor, Michigan 48103, USA.
Angelo Gaitas

Funding

Novel single cell disease markers with a hybrid AFM scanning piezo-thermal probeR43GM084520 · NIGMS · KYTARO, INC. · PI GAITAS, ANGELO · 2008 to 2009
$400k
NIGMS NIH HHS R43 GM084520
6 · The paper itself

Abstract

This paper demonstrates a thermally actuated tapping mode atomic force microscopy (AFM) with a polymer cantilever. The cantilever (350x250x3 microm(3)) is made from polyimide and includes an embedded resistive heater for thermal actuation. The oscillation of the cantilever is due to the stress gradient caused by alternating heating and cooling from the periodic ac excitation of the heater. The tip oscillation amplitude is 5-10 nm in air. The oscillation occurs at 2omega and is a linear function of the applied voltage. The maximum oscillation amplitude is seen at 0.8 Hz with a 3dB frequency of 26 Hz. The damping of the oscillation due to tip-sample interaction is used to image the sample without any optomechanical feedback. Scans with a 200 nm tall grating indicate a resolution comparable to deflection signal from the AFM in contact mode.

Identifiers

PMID19256649
PMCPMC10550333

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked