Evidence map›Paper›PMID 19215065›Full record

ArticleAnalytical chemistry2009

Surface plasmon resonance detection using antibody-linked magnetic nanoparticles for analyte capture, purification, concentration, and signal amplification.

Scott D Soelberg, Richard C Stevens, Ajit P Limaye, Clement E Furlong

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 38 papers.

0numbers the graph read from it
0cells of the map it votes in
38citing papers in PubMed
11.0field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

38 citing papers in PubMed, 170 citations in OpenAlex.

  1. Article
  2. Rapid and Sensitive Detection ofMicroorganisms · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Detection ofBiosensors · 2019
    Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Detection and identification ofEngineering in life sciences · 2018
    Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Scott D SoelbergDepartment of Medicine-Division of Medical Genetics and Genome Sciences, University of Washington, Seattle, Washington 98195, USA.
Richard C Stevens
Ajit P Limaye
Clement E Furlong
University of Washington Medical Center · US

Funding

Toxic AlgaeP50ES012762 · NIEHS · UNIVERSITY OF WASHINGTON · PI FAUSTMAN, ELAINE M · 2004 to 2009
$2.6M
NIEHS NIH HHS P50 ES012762
6 · The paper itself

Abstract

Rapid, sensitive, and accurate detection of analytes present in low concentrations in complex matrixes is a critical challenge. One issue that affects many biosensor protocols is the number and nature of the interferences present in complex matrixes such as plasma, urine, stool, and environmental samples, resulting in loss of sensitivity and specificity. We have developed a method for rapid purification, concentration, and detection of target analytes from complex matrixes using antibody-coated superparamagnetic nanobeads (immunomagnetic beads, or IMBs). The surface plasmon resonance (SPR) detection signal from staphylococcal enterotoxin B (SEB) was dramatically increased when the IMBs were used as detection amplifiers. When SEB detection included a 10-fold concentration/purification IMB protocol, a substantial increase in detection sensitivity was observed. This procedure was used to successfully purify and concentrate SEB from serum and stool samples, then amplify the SPR detection signal. SEB at a concentration of 100 pg/mL was easily detected in both buffer and stool samples using this procedure. The IMB protocol also served to verify the analyte detection by using two different anti-SEB antibodies, mouse monoclonal antibodies attached to the magnetic nanobeads and rabbit polyclonal antibodies on the SPR sensor surface. Multiple detections of SEB in stool were performed using the same sensor surface by regenerating the sensor surfaces with a pH 2.2 buffer wash.

Indexed as

AnimalsAntibodiesBiosensing TechniquesEnterotoxinsMagneticsMiceNanoparticlesRabbitsSurface Plasmon ResonanceAntibodiesenterotoxin B, staphylococcalEnterotoxins

Identifiers

PMID19215065
PMCPMC2880624
OpenAlexW2104987759

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.