Monitoring thrombin generation by electrochemistry: development of an amperometric biosensor screening test for plasma and whole blood.

Charles Thuerlemann, André Haeberli, Lorenzo Alberio

Open access · bronzeAbstract read
PubMed Publisher
In one paragraph

Article in Clinical chemistry, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 40 citations in OpenAlex.

  1. Electrochemical Monitoring in Anticoagulation Therapy.Molecules (Basel, Switzerland) · 2024
    Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Systems Analysis of Thrombus Formation.Circulation research · 2016
    Review
  9. Miniaturized technology for protein and nucleic acid point-of-care testing.Translational research : the journal of laboratory and clinical medicine · 2012
    Review
  10. Biosensors in clinical chemistry - 2011 update.Clinica chimica acta; international journal of clinical chemistry · 2011
    Review
  11. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Charles ThuerlemannDepartment of Haematology and Central Haematology Laboratory, Inselspital, Bern University Hospital, University of Bern, Switzerland. charles.thuerlemann@bluewin.ch
André Haeberli
Lorenzo Alberio
University of Bern · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundComplete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma.

methodsThe measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin.

resultsIncreasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples.

conclusionsThe biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.

Indexed as

Biosensing TechniquesBlood Chemical AnalysisElectrochemistryHumansThrombinThrombin

Identifiers

PMID19147731
OpenAlexW1990628713