Evidence map›Paper›PMID 19117571›Full record

ArticleJournal of biomechanics2009

Asymmetrical strain distributions and neutral axis location of cartilage in flexure.

Gregory M Williams, Kenneth R Gratz, Robert L Sah

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanics, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Shape fidelity of native and engineered human nasal septal cartilage.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2013
    Article
  3. Flexural properties of native and tissue-engineered human septal cartilage.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2013
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Gregory M WilliamsDepartment of Bioengineering, University of California, San Diego, 9500 Gilman Drive, Mail Code 0412, La Jolla, CA 92093, USA.
Kenneth R Gratz
Robert L Sah
University of California, San Diego · US

Funding

Developing Articular Cartilage: Function &RemodelingR01AR044058 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI SAH, ROBERT L · 2000 to 2010
$3.3M
Howard Hughes Medical InstituteNIAMS NIH HHS R01 AR044058
6 · The paper itself

Abstract

Flexural deformation has been used for the biomechanical characterization of native and engineered cartilage and as a mechanical stimulus to induce alteration of cartilage shape during in vitro culture. Flexure is also a physiologically relevant mode of deformation for various cartilaginous structures such as the ears and nose, but a kinematic description of cartilage in flexure is lacking even for simple deformations. The hypothesis of this study was that tension-compression (T-C) nonlinearity of cartilage will result in asymmetrical strain distributions during bending, while a material with similar behavior in tension and compression, such as alginate, will have a more symmetrical distribution of strains. Strips of calf articular cartilage and alginate were tested under uniform circular bending, and strains were determined by a micromechanical analysis of images acquired by epifluorescence microscopy. This experimental analysis was interpreted in the context of a model of small-deflection, pure bending of thin, homogeneous beams of a bimodular elastic material. The results supported the hypothesis and showed that marked asymmetry existed in cartilage flexural strains where the location of the neutral axis was significantly different than the midline and closer to the tensile surface. In contrast, alginate samples had a centrally located neutral axis. These experimental results were supported by the model indicating that the bimodular simplification of cartilage properties is a useful first approximation of T-C nonlinearity in these tests. The neutral axis location in cartilage samples was not influenced by the testing orientation (towards or away from the superficial-most tissue) or magnitude of flexure. These findings characterize the kinematics of cartilage at equilibrium during simple bending and indicate that T-C nonlinearity is an important determinant of the flexural strain distributions in the tested tissue.

Indexed as

AlginatesAnimalsBiomechanical PhenomenaCartilage, ArticularCattleCompressive StrengthGlucuronic AcidHexuronic AcidsAlginatesGlucuronic AcidHexuronic Acids

Identifiers

PMID19117571
PMCPMC2673500
OpenAlexW2073393995

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.